The sensitivity and specificity of TOP, FDP and GDX in screening for early glaucoma.

نویسندگان

  • K Fabré
  • I Michiels
  • T Zeyen
چکیده

The purpose of this study was to evaluate the efficacy of three screening tests in detecting glaucoma in its early stage: the Tendency Oriented Perimetry (TOP) and Frequency Doubling Perimetry (FDP) visual field tests, and the Glaucoma Diagnostic (GDx) nerve fibre layer analyser. Eighteen patients with glaucoma who showed an early defect on HFA c 24-2 and twenty normals underwent the three tests. TOP showed a sensitivity of 94.4% and a specificity of 75%, FDP showed a sensitivity of 72.2% and a specificity of 100%, and GDx a sensitivity of 77.7% and a specificity of 60%.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity and specificity of scanning laser polarimetry using the GDx.

BACKGROUND/AIMS To determine the sensitivity and the specificity of the GDx in the detection of (1) advanced glaucoma, (2) early glaucoma, and (3) nerve fibre bundle defects (NFBD). METHODS Group A comprised 20 eyes with reproducible glaucomatous visual field defects confirmed by octopus perimetry, group B consisted of 10 eyes with normal visual fields but either glaucomatous NFBD or deterior...

متن کامل

SCIENTIFIC REPORT Sensitivity and specificity of scanning laser polarimetry using the GDx

Background/aims: To determine the sensitivity and the specificity of the GDx in the detection of (1) advanced glaucoma, (2) early glaucoma, and (3) nerve fibre bundle defects (NFBD). Methods: Group A comprised 20 eyes with reproducible glaucomatous visual field defects confirmed by octopus perimetry, group B consisted of 10 eyes with normal visual fields but either glaucomatous NFBD or deterior...

متن کامل

Using optical imaging summary data to detect glaucoma.

PURPOSE To evaluate the sensitivity and specificity for discriminating between early to moderate glaucomatous and normal eyes using summary data reports from the Heidelberg Retina Tomograph (HRT), the GDx Nerve Fiber Analyzer (GDx), and the Optical Coherence Tomograph (OCT). DESIGN Comparative cross-sectional study PARTICIPANTS One eye each of 50 normal subjects and 39 glaucoma patients wit...

متن کامل

Ability of scanning laser polarimetry (GDx) to discriminate among early glaucomatous, ocular hypertensive and normal eyes in the Korean population.

We investigated the ability of the GDx-Nerve Fiber Analyzer (NFA) to discriminate between normal and early glaucomatous eyes among Korean individuals by reviewing the medical records of 217 consecutive subjects: 61 early glaucoma patients, 68 ocular hypertensive patients, and 88 normal subjects. GDx parameters were compared using ANOVA. The Receiver Operating Characteristics (ROC) curve for eac...

متن کامل

ارزش تشخیصی محصولات حاصل از تجزیه فیبرین / فیبرینوژن و مقایسه آن با سیتولوژی در تشخیص تومور مثانه

Diagnostic Value of Fibrin/Fibrinogen Degradation Products and its Comparsion with Urine Cytology in the Diagnosis of Bladder Carcinoma M.R. Moein MD , V. Dehghani MD Received: 16/06/06 Sent for Revision: 01/11/06 Received Revised Manuscript: 05/02/07 Accepted: 12/03/07 Background and Objective: The bladder tumar is common in urinary system and its certain diagnostic method is cystos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Bulletin de la Societe belge d'ophtalmologie

دوره 275  شماره 

صفحات  -

تاریخ انتشار 2000