Endoscopic removal of an eroded magnetic sphincter augmentation device.

نویسندگان

  • Baldwin Po Man Yeung
  • Grant Fullarton
چکیده

Magnetic sphincter augmentation with the LINX device (Torax Medical, Shoreview, Minnesota, USA) is an effective treatment for gastroesophageal reflux disease (GERD). It is associated with shorter operating time and lower rate of gas bloat [1]. Erosion is estimated to range from 0.1% to 1.2%; it may be higher with the smaller device. The most common method for device removal involves a combined endoscopic-laparoscopic approach [2, 3]. Endoscopic removal using a bipolar grasping device has also been reported [4]. We report the first case of LINX erosion in the United Kingdom and its endoscopic removal using Olympus loop cutters. A 57-year-old woman with GERD underwent LINX implantation in April 2013 (▶Fig. 1). She did not have a hiatus hernia and manometry was normal. Good reflux control was achieved. In February 2017, the patient experienced acute intermittent dysphagia and chest pain. Endoscopy showed device erosion. Under general anesthesia, the LINX device was divided at two points using a loop cutter (Olympus Medical Systems Corp., Tokyo, Japan), and was extracted endoscopically using a grasper with the application of rotational traction. The mucosal defects in the esophagus were closed with two Olympus QuickClips (▶Video1). The patient was discharged with proton pump inhibitors on postoperative Day 1 after a normal oral contrast swallow study (▶Fig. 2).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety analysis of first 1000 patients treated with magnetic sphincter augmentation for gastroesophageal reflux disease.

Antireflux surgery with a magnetic sphincter augmentation device (MSAD) restores the competency of the lower esophageal sphincter with a device rather than a tissue fundoplication. As a regulated device, safety information from the published clinical literature can be supplemented by tracking under the Safe Medical Devices Act. The aim of this study was to examine the safety profile of the MSAD...

متن کامل

Endoscopic Management of Eroded Bands Following Banded-Gastric Bypass (with Video).

BACKGROUND Banded-gastric bypass is a highly effective bariatric procedure, yet the possibility of band erosion remains a significant drawback. Surgical removal of eroded bands may be associated with significant morbidity. In this study, we assess the efficacy and safety of a solely peroral endoscopic approach for the management of eroded bands in patients with a banded-gastric bypass. MATERI...

متن کامل

Endoscopic Management of Gastroesophageal Reflux Disease: Revisited

Gastroesophageal reflux disease (GERD) is defined by the presence of troublesome symptoms resulting from the reflux of gastric contents. The prevalence of GERD is increasing globally. An incompetent lower esophageal sphincter underlies the pathogenesis of GERD. Proton pump inhibitors (PPIs) form the core of GERD management. However, a substantial number of patients do not respond well to PPIs. ...

متن کامل

Modern GERD treatment: feasibility of minimally invasive esophageal sphincter augmentation.

BACKGROUND Gastroesophageal reflux disease (GERD) is a common chronic disease requiring adequate treatment since it represents one major cause of development of Barrett's esophagus and eventually carcinoma. Novel laparoscopic magnetic sphincter augmentation for GERD was evaluated prospectively. PATIENTS AND METHODS A total of 23 patients with GERD underwent minimally invasive implantation of ...

متن کامل

Magnetic Sphincter Augmentation for Gastroesophageal Reflux at 5 Years: Final Results of a Pilot Study Show Long-Term Acid Reduction and Symptom Improvement

BACKGROUND As previously reported, the magnetic sphincter augmentation device (MSAD) preserves gastric anatomy and results in less severe side effects than traditional antireflux surgery. The final 5-year results of a pilot study are reported here. PATIENTS AND METHODS A prospective, multicenter study evaluated safety and efficacy of the MSAD for 5 years. Prior to MSAD placement, patients had...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Endoscopy

دوره 49 7  شماره 

صفحات  -

تاریخ انتشار 2017