Potential Effectiveness of Point-of-Use Filtration to Address Risks to Drinking Water in the United States

نویسندگان

  • Kathleen Ward Brown
  • Bemnet Gessesse
  • Lindsey J Butler
  • David L MacIntosh
چکیده

Numerous contemporary incidents demonstrate that conventional control strategies for municipal tap water have limited ability to mitigate exposures to chemicals whose sources are within distribution systems, such as lead, and chemicals that are not removed by standard treatment technologies, such as perfluorooctanoic acid (PFOA)/perfluorooctanesulfonic acid (PFOS). In these situations, point-of-use (POU) controls may be effective in mitigating exposures and managing health risks of chemicals in drinking water, but their potential utility has not been extensively examined. As an initial effort to fill this information gap, we conducted a critical review and analysis of the existing literature and data on the effectiveness of POU drinking water treatment technologies for reducing chemical contaminants commonly found in tap water in the United States. We found that many types of water treatment devices available to consumers in the United States have undergone laboratory testing and often certification for removal of chemical contaminants in tap water, but in most cases their efficacy in actual use has yet to be well characterized. In addition, the few studies of POU devices while "in use" focus on traditional contaminants regulated under the Safe Drinking Water Act, but do not generally consider nontraditional contaminants of concern, such as certain novel human carcinogens, industrial chemicals, pesticides, pharmaceuticals, personal care products, and flame retardants. Nevertheless, the limited information available at present suggests that POU devices can be highly effective when used prophylactically and when deployed in response to contamination incidents. Based on these findings, we identify future areas of research for assessing the ability of POU filters to reduce health-related chemical contaminants distributed through public water systems and private wells.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of water supply system and water quality of Lighvan village using water safety plan

Background: Continuous expansion of potable water pollution sources is one of the main concerns of water suppliers, therefore measures such as water safety plan (WSP), have been taken into account to control these sources of pollution. The aim of this study was to identify probable risks and threatening hazards to drinking water quality in Lighvan village along with assessment of bank filtratio...

متن کامل

The Effectiveness of Arsenic Remediation from Groundwater in a Private Home

Private wells are the source of drinking water for approximately 15% of households in the United States, but these wells are not regulated or monitored by government agencies. The well waters can contain arsenic, a known carcinogen that occurs in groundwater throughout the nation at concentrations that can exceed the Maximum Contaminant Level defined by the U.S. Environmental Protection Agency ...

متن کامل

تعیین غلظت پرکلرات در آب و خاک سطحی مناطق جنگی (مطالعه موردی: شهرستان خرمشهر)

Background and Objectives: Perchlorate, as an emerging contaminant, has attracted notice of the most individuals and organizations. Presence of perchlorate in the human body can lead to inappropriate regulation of metabolism in adults. Moreover, due to inhibition of iodide uptake in the thyroid gland, it causes neurological and behavioral problems in infants and children. United States Environm...

متن کامل

Performance Evaluation of Point-Of-Use Drinking Water Treatment Units in Removal of Heavy Metals and Dissolved Solids from Drinking Water Supply in Tabriz

Introduction: Application of point-of-use (POU) drinking water treatment units is expanding across the world due to the increased concerns about the adverse health effects of water pollution. The main treatment systems of these devices are mostly activated carbon and nano-filter or reverse osmosis. Materials and Methods: This study was conducted to evaluate the effect of using POU units on phy...

متن کامل

Nanoparticles Retention Potential of Multichannel Hollow Fiber Drinking Water Production Membrane

This study aims to investigate the potential of nanoparticle retention of ultrafi ltration (UF) multichannel hollow fiber membrane. Filtration experiments of fl uorescent silica nanoparticles (NPs) (10 and 100 nm) and CdTe quantum dots (1.5 nm) suspensions were carried out under diff erent operating conditions to analyze the retention rate (RT), the fouling zone and the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -