Performance Characteristics of the Agilent 1290 Infinity Evaporative Light Scattering Detector

ثبت نشده
چکیده

The Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD) provides a wide detection range for a variety of compounds with excellent sensitivity, down to low-nanogram levels, better efficiency and greater reproducibility. It is perfect for the analysis of semivolatile and nonvolatile compounds and compounds without UV chromophores such as most amino acids and sugars. The 1290 Infinity ELSD does not rely on the optical properties of a compound and is able to measure compounds without the need for derivatization and tedious sample preparation. This Technical Overview demonstrates the improved sensitivity and performance of the 1290 Infinity ELSD coupled with the Agilent 1290 Infinity LC System. The 1290 Infinity ELSD is significantly more sensitive than any other ELSD and gives good data even in low concentrations. Author Bettina Schuhn Agilent Technologies, Inc. Waldbronn, Germany mV 400

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Sweeteners, Preservatives, and Caffeine in Various Food and Consumer Products Using the Agilent 1290 Infi nity II LC

The Agilent 1290 Infi nity II LC was used to analyze additives such as sweeteners, preservatives, and caffeine in various food products, beverages, and consumer toothpaste. The developed method facilitates accurate and sensitive determination of nine additives using a diode array detector (DAD) and an evaporative light scattering detector (ELSD) placed in series. After the DAD, a valve was inst...

متن کامل

Analysis of TCM injections using the Agilent 1290 Infinity LC system

An ultra high performance liquid chromatography (UHPLC) method using an Agilent 1290 Infinity LC system with an Agilent 1290 Infinity Diode Array Detector (DAD) was developed for the separation of Shenmai injections. Good separation of complex systems was achieved by connecting two columns: an Agilent ZORBAX Eclipse Plus C18 column (2.1 mm × 100 mm, 1.8 μm) and an Agilent ZORBAX SB C18 (2.1mm ×...

متن کامل

Analysis of Radix Bupleuri (Chaihu) using Agilent 1200 Series LC Systems with Evaporative Light Scattering Detector

This Application Note describes the development of conventional HPLC and Rapid Resolution LC (RRLC) methods for the analysis of Buplerui (Chaihu). A comparison of fingerprint chromatograms of different Buplerui samples showed different peak profiles of different TCMs collected from different places. The method for the Agilent 1200 Series Evaporative Light Scattering Detector (ELSD) was optimize...

متن کامل

Performance of the Agilent 1290 Infinity Quaternary Pump using Trifluoroacetic Acid (TFA) as the mobile phase modifier

In liquid chromatography, baseline noise should be as low as possible to provide an optimum signal-to-noise ratio and to enable reliable integration of peaks at trace level. Baseline noise has different sources. One source is the detector, and another is the mixing performance of the pump, which is especially important if, for example, trifluoroacetic acid (TFA) is used as modifier in the mobil...

متن کامل

Transferring and optimizing the determination of explosives to fast and high resolution chromatography

This Application Note describes the method for detection of nanogram levels of explosive constituents in seawater samples, after explosion of ordnance devices. Sample preparation is done by enrichment on highly cross-linked polystyrenedivinylbenzene (PS-DVB) cartridges such as the Agilent SampliQ PS-DVB. The improved chromatographic method was developed using the Method Development System from ...

متن کامل