Performance Characteristics of the Agilent 1290 Infinity Evaporative Light Scattering Detector
ثبت نشده
چکیده
The Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD) provides a wide detection range for a variety of compounds with excellent sensitivity, down to low-nanogram levels, better efficiency and greater reproducibility. It is perfect for the analysis of semivolatile and nonvolatile compounds and compounds without UV chromophores such as most amino acids and sugars. The 1290 Infinity ELSD does not rely on the optical properties of a compound and is able to measure compounds without the need for derivatization and tedious sample preparation. This Technical Overview demonstrates the improved sensitivity and performance of the 1290 Infinity ELSD coupled with the Agilent 1290 Infinity LC System. The 1290 Infinity ELSD is significantly more sensitive than any other ELSD and gives good data even in low concentrations. Author Bettina Schuhn Agilent Technologies, Inc. Waldbronn, Germany mV 400
منابع مشابه
Determination of Sweeteners, Preservatives, and Caffeine in Various Food and Consumer Products Using the Agilent 1290 Infi nity II LC
The Agilent 1290 Infi nity II LC was used to analyze additives such as sweeteners, preservatives, and caffeine in various food products, beverages, and consumer toothpaste. The developed method facilitates accurate and sensitive determination of nine additives using a diode array detector (DAD) and an evaporative light scattering detector (ELSD) placed in series. After the DAD, a valve was inst...
متن کاملAnalysis of TCM injections using the Agilent 1290 Infinity LC system
An ultra high performance liquid chromatography (UHPLC) method using an Agilent 1290 Infinity LC system with an Agilent 1290 Infinity Diode Array Detector (DAD) was developed for the separation of Shenmai injections. Good separation of complex systems was achieved by connecting two columns: an Agilent ZORBAX Eclipse Plus C18 column (2.1 mm × 100 mm, 1.8 μm) and an Agilent ZORBAX SB C18 (2.1mm ×...
متن کاملAnalysis of Radix Bupleuri (Chaihu) using Agilent 1200 Series LC Systems with Evaporative Light Scattering Detector
This Application Note describes the development of conventional HPLC and Rapid Resolution LC (RRLC) methods for the analysis of Buplerui (Chaihu). A comparison of fingerprint chromatograms of different Buplerui samples showed different peak profiles of different TCMs collected from different places. The method for the Agilent 1200 Series Evaporative Light Scattering Detector (ELSD) was optimize...
متن کاملPerformance of the Agilent 1290 Infinity Quaternary Pump using Trifluoroacetic Acid (TFA) as the mobile phase modifier
In liquid chromatography, baseline noise should be as low as possible to provide an optimum signal-to-noise ratio and to enable reliable integration of peaks at trace level. Baseline noise has different sources. One source is the detector, and another is the mixing performance of the pump, which is especially important if, for example, trifluoroacetic acid (TFA) is used as modifier in the mobil...
متن کاملTransferring and optimizing the determination of explosives to fast and high resolution chromatography
This Application Note describes the method for detection of nanogram levels of explosive constituents in seawater samples, after explosion of ordnance devices. Sample preparation is done by enrichment on highly cross-linked polystyrenedivinylbenzene (PS-DVB) cartridges such as the Agilent SampliQ PS-DVB. The improved chromatographic method was developed using the Method Development System from ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2013