Scanning Electrochemical Microscopy. 37. Light Emission by Electrogenerated Chemiluminescence at SECM Tips and Their Application to Scanning Optical Microscopy

نویسندگان

  • Fu-Ren F. Fan
  • David Cliffel
  • Allen J. Bard
چکیده

Electrogenerated chemiluminescence (ECL) at a scanning electrochemical microscope (SECM) tip as the tip was moved in the vicinity of insulating and conductive substrates was studied either by ion annihilation or with a coreactant. The SECM/ECL approach curves (intensity vs tip-substrate distance, d) with both insulating and conducting substrates showed a decrease in ECL intensity with a decrease in d. Modes of operation that produced sufficiently intense and stable ECL for optical imaging are possible. The needed improvements for higher resolution and the potential application of this technique for the studies of the kinetics and mechanisms of coreactant ECL reactions are discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scanning electrochemical microscopy study of ion annihilation electrogenerated chemiluminescence of rubrene and [Ru(bpy)3]2+.

Scanning electrochemical microscopy (SECM) was used for the study of electrogenerated chemiluminescence (ECL) in the radical annihilation mode. The concurrent steady-state generation of radical ions in the microgap formed between a SECM probe and a transparent microsubstrate provides a distance-dependent ECL signal that can provide information about the kinetics, stability, and mechanism of the...

متن کامل

Scanning Electrochemical Microscopy Study of Ion Annihilation Electrogenerated Chemiluminescence of Rubrene and [Ru(bpy)<sub>3</sub>]<sup>2+</sup>

Scanning electrochemical microscopy (SECM) was used for the study of electrogenerated chemiluminescence (ECL) in the radical annihilation mode. The concurrent steady-state generation of radical ions in the microgap formed between a SECM probe and a transparent microsubstrate provides a distancedependent ECL signal that can provide information about the kinetics, stability, and mechanism of the ...

متن کامل

Combined scanning electrochemical/optical microscopy with shear force and current feedback.

A technique that combines scanning electrochemical microscopy (SECM) and scanning optical microscopy (OM) was developed. Simultaneous scanning electrochemical/optical microscopy (SECM/OM) was performed by a special probe tip, which consists of an optical fiber core for light passage, surrounded by a gold ring electrode, and an outermost electrophoretic insulating sheath, with the tip attached t...

متن کامل

Fabrication and characterization of probes for combined scanning electrochemical/optical microscopy experiments.

A technique that combines scanning electrochemical microscopy (SECM) and optical microscopy (OM) was implemented with a new probe tip. The tip for scanning electrochemicaVoptical microscopy (SECM/OM) was constructed by insulating a typical gold-coated near-field scanning optical microscopy tip using electrophoretic anodic paint. Once fabricated, the tip was characterized by steady-state cyclic ...

متن کامل

Electrogenerated chemiluminescence (ECL) 79. Reductive-oxidation ECL of tris(2,2′-bipyridine)ruthenium(II) using hydrogen peroxide as a coreactant in pH 7.5 phosphate buffer solution

Hydrogen peroxide (H2O2) can be used as a coreactant to generate reductive-oxidation ECL of Tris(2,2′-bipyridine)ruthenium(II), Ru(bpy)3 (bpy = 2,2′-bipyridine), in pH 7.5 phosphate buffer solution (PBS). Although Ru(bpy)3 is adsorbed and precipitated on the electrode upon reduction of Ru(bpy)3 in aqueous solutions, ECL can still be generated and scanning electrochemical microscopy (SECM) e r o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998