A Randomized Trial of a Schlemm's Canal Microstent with Phacoemulsification for Reducing Intraocular Pressure in Open-Angle Glaucoma.

نویسندگان

  • Norbert Pfeiffer
  • Julian Garcia-Feijoo
  • Jose M Martinez-de-la-Casa
  • Jose M Larrosa
  • Antonio Fea
  • Hans Lemij
  • Stefano Gandolfi
  • Oliver Schwenn
  • Katrin Lorenz
  • Thomas W Samuelson
چکیده

PURPOSE To assess the safety and effectiveness of the Hydrus Microstent (Ivantis, Inc, Irvine, CA) with concurrent cataract surgery (CS) for reducing intraocular pressure (IOP) in open-angle glaucoma (OAG). DESIGN Prospective, multicenter, randomized, single-masked, controlled clinical trial. PARTICIPANTS One hundred eyes from 100 patients 21 to 80 years of age with OAG and cataract with IOP of 24 mmHg or less with 4 or fewer hypotensive medications and a washed-out diurnal IOP (DIOP) of 21 to 36 mmHg. METHODS On the day of surgery, patients were randomized 1:1 to undergo CS with the microstent or CS alone. Postoperative follow-up was at 1 day, 1 week, and 1, 3, 6, 12, 18, and 24 months. Washout of hypotensive medications was repeated at 12 and 24 months. MAIN OUTCOME MEASURES Response to treatment was defined as a 20% or more decrease in washed out DIOP at 12 and 24 months of follow-up compared with baseline. Mean DIOP at 12 and 24 months, the proportion of subjects requiring medications at follow-up, and the mean number of medications were analyzed. Safety measures included change in visual acuity, slit-lamp observations, and adverse events. RESULTS The proportion of patients with a 20% reduction in washed out DIOP was significantly higher in the Hydrus plus CS group at 24 months compared with the CS group (80% vs. 46%; P = 0.0008). Washed out mean DIOP in the Hydrus plus CS group was significantly lower at 24 months compared with the CS group (16.9±3.3 mmHg vs. 19.2±4.7 mmHg; P = 0.0093), and the proportion of patients using no hypotensive medications was significantly higher at 24 months in the Hydrus plus CS group (73% vs. 38%; P = 0.0008). There were no differences in follow-up visual acuity between groups. The only notable device-related adverse event was focal peripheral anterior synechiae (1-2 mm in length). Otherwise, adverse event frequency was similar in the 2 groups. CONCLUSIONS Intraocular pressure was clinically and statistically significantly lower at 2 years in the Hydrus plus CS group compared with the CS alone group, with no differences in safety.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Quarter Century's Progress in the Treatment of Open-Angle Glaucoma.

The publication this month of “A Randomized Trial of a Schlemm’s Canal Microstent with Phacoemulsification for Reducing Intraocular Pressure in Open Angle Glaucoma” by Pfieffer et al (see http://www.aaojournal.org/article/ S0161-6420(15)00315-2/abstract), describing a promising new treatment for glaucoma, has stimulated this reflection of how glaucoma therapy has changed in the past quarter cen...

متن کامل

Two-Year COMPASS Trial Results: Supraciliary Microstenting with Phacoemulsification in Patients with Open-Angle Glaucoma and Cataracts.

PURPOSE We evaluated 2-year safety and efficacy of supraciliary microstenting (CyPass Micro-Stent; Transcend Medical, Inc., Menlo Park, CA) for treating mild-to-moderate primary open-angle glaucoma (POAG) in patients undergoing cataract surgery. DESIGN Multicenter (24 US sites), interventional randomized clinical trial (RCT) (ClinicalTrials.gov identifier, NCT01085357). PARTICIPANTS Subject...

متن کامل

iStent trabecular micro-bypass stent for open-angle glaucoma

Trabecular micro-bypass stents, commonly known as iStents, are micro-invasive glaucoma surgery (MIGS) devices used to treat open-angle glaucoma. Like other MIGS procedures that enhance trabecular outflow, the iStent lowers intraocular pressure (IOP) by creating a direct channel between the anterior chamber and Schlemm's canal. iStents are typically implanted at the time of phacoemulsification f...

متن کامل

Ab interno trabeculectomy: patient selection and perspectives

Ab interno trabeculectomy is one among several recently introduced minimally invasive glaucoma surgeries that avoid a conjunctival incision and full-thickness sclerostomy involved in traditional glaucoma surgery. Ablation of the trabecular meshwork and inner wall of Schlemm's canal is performed in an arcuate fashion via a clear corneal incision, alone or in combination with phacoemulsification ...

متن کامل

Schlemm’s Canal and Trabecular Meshwork in Eyes with Primary Open Angle Glaucoma: A Comparative Study Using High-Frequency Ultrasound Biomicroscopy

We investigated in vivo changes in Schlemm's canal and the trabecular meshwork in eyes with primary open angle glaucoma (POAG). Relationships between Schlemm's canal diameter, trabecular meshwork thickness, and intraocular pressure (IOP) were examined. Forty POAG patients and 40 normal individuals underwent 80-MHz Ultrasound Biomicroscopy examinations. The Schlemm's canal and trabecular meshwor...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 122 7  شماره 

صفحات  -

تاریخ انتشار 2015