A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: the RELEVANT [Role of long dEtection window programming in patients with LEft VentriculAr dysfunction, Non-ischemic eTiology in primary prevention treated with a biventricular ICD] study
نویسندگان
چکیده
AIMS To investigate the efficacy and safety of a cardiac resynchronization therapy with cardioverter-defibrillator (CRT-D) device with simplified ventricular tachycardia management in patients with non-ischaemic heart failure (HF) and primary prevention implantable cardioverter defibrillator (ICD) indication. METHODS AND RESULTS Prospective, controlled, parallel, multicentre, non-randomized study enrolling 324 primary prevention non-ischaemic HF patients implanted with CRT-D devices from 2004 to 2007: Protect group, 164 patients implanted with a Medtronic Insync III Protect device and Control group, 160 patients utilizing other Medtronic CRT-D devices. Efficacy was assessed by computing appropriate and inappropriate detections and therapies during follow-up; safety compared hospitalizations and syncopal events between groups. Ninety per cent of both ventricular and supraventricular tachyarrhythmias terminated within the 13-29 beat detection interval with the Protect algorithm. The Protect group showed a significantly better event-free survival to first delivered therapy for total (P = 0.0001), appropriately treated (P = 0.002), and inappropriately treated episodes (P = 0.017). The total number of delivered shocks was significantly lower in the Protect group (22 vs. 59, P < 0.0001). In the Protect group, a significantly reduced HF hospitalization (hazard ratio 0.38, 95% CI 0.15-0.98, P = 0.044) was observed without any increase of syncope or death. CONCLUSION A simplified CRT-D device with fixed long detection reduced overall ICD therapy burden and HF hospitalizations without entailing any additional adverse events in primary prevention non-ischaemic HF patients.
منابع مشابه
Not too late, not too fast!!
This editorial refers to ‘A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: the RELEVANT [Role of long dEtection window programming in patients with LEft VentriculAr dysfunction, Non-ische...
متن کاملImpact of programming strategies aimed at reducing nonessential implantable cardioverter defibrillator therapies on mortality: a systematic review and meta-analysis.
BACKGROUND Patients who receive implantable cardioverter defibrillator therapies are at higher risk of death versus those who do not. Programmed settings to reduce nonessential implantable cardioverter defibrillator therapies (therapy reduction programming) have been developed but may have adverse effects. This systematic review and meta-analysis assessed the relationship between therapy reduct...
متن کاملCardiac resynchronization therapy in ischemic and non-ischemic cardiomyopathy
Cardiac resynchronization therapy (CRT) using a biventricular pacing system has been an effective therapeutic strategy in patients with symptomatic heart failure with a reduced left ventricular ejection fraction (LVEF) of 35% or less and a QRS duration of 130 ms or more. The etiology of heart failure can be classified as either ischemic or non-ischemic cardiomyopathy. Ischemic etiology of patie...
متن کاملEffectiveness of Implantable Cardioverter-Defibrillator Therapy for Heart Failure Patients according to Ischemic or Non-Ischemic Etiology in Korea
BACKGROUND AND OBJECTIVES This study was performed to describe clinical characteristics of patients with left ventriculars (LV) dysfunction and implantable cardioverter-defibrillator (ICD), and to evaluate the effect of ICD therapy on survival in Yeongnam province of Korea. SUBJECTS AND METHODS From a community-based device registry (9 centers, Yeongnam province, from November 1999 to Septemb...
متن کاملDeath Without Prior Appropriate Implantable Cardioverter-Defibrillator Therapy A Competing Risk Study
Background—Implantable cardioverter-defibrillators (ICDs) improve survival in selected patients with left ventricular systolic dysfunction in randomized trials. Competing death without prior appropriate ICD therapy might preclude benefit from ICD implantation in a less selected routine-care population. Methods and Results—We selected all patients with ischemic or dilated cardiomyopathy with an ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 30 شماره
صفحات -
تاریخ انتشار 2009