Factors influencing individual variation in perceptual directional microphone benefit.
نویسندگان
چکیده
BACKGROUND Large variations in perceptual directional microphone benefit, which far exceed the variation expected from physical performance measures of directional microphones, have been reported in the literature. The cause for the individual variation has not been systematically investigated. PURPOSE To determine the factors that are responsible for the individual variation in reported perceptual directional benefit. RESEARCH DESIGN A correlational study. Physical performance measures of the directional microphones obtained after they had been fitted to individuals, cognitive abilities of individuals, and measurement errors were related to perceptual directional benefit scores. STUDY SAMPLE Fifty-nine hearing-impaired adults with varied degrees of hearing loss participated in the study. DATA COLLECTION AND ANALYSIS All participants were bilaterally fitted with a Motion behind-the-ear device (500 M, 501 SX, or 501 P) from Siemens according to the National Acoustic Laboratories' non-linear prescription, version two (NAL-NL2). Using the Bamford-Kowal-Bench (BKB) sentences, the perceptual directional benefit was obtained as the difference in speech reception threshold measured in babble noise (SRTn) with the devices in directional (fixed hypercardioid) and in omnidirectional mode. The SRTn measurements were repeated three times with each microphone mode. Physical performance measures of the directional microphone included the angle of the microphone ports to loudspeaker axis, the frequency range dominated by amplified sound, the in situ signal-to-noise ratio (SNR), and the in situ three-dimensional, articulation-index weighted directivity index (3D AI-DI). The cognitive tests included auditory selective attention, speed of processing, and working memory. Intraparticipant variation on the repeated SRTn's and the interparticipant variation on the average SRTn were used to determine the effect of measurement error. A multiple regression analysis was used to determine the effect of other factors. RESULTS Measurement errors explained 52% of the variation in perceptual directional microphone benefit (95% confidence interval [CI]: 34-78%), while another 37% of variation was explained primarily by the physical performance of the directional microphones after they were fitted to individuals. The most contributing factor was the in situ 3D AI-DI measured across the low frequencies. CONCLUSIONS Repeated SRTn measurements are needed to obtain a reliable indication of the perceptual directional benefit in an individual. Further, to obtain optimum benefit from directional microphones, the effectiveness of the microphones should be maximized across the low frequencies.
منابع مشابه
Benefit From Directional Microphone Hearing Aids: Objective and Subjective Evaluations
OBJECTIVES The aims of this study were to find and compare the effect of directional (DIR) processing of two different hearing aids via both subjective and objective methods, to determine the association between the results of the subjective and objective evaluations, and to find out individual predictive factors influencing the DIR benefit. METHODS Twenty-six hearing aid users fitted unilate...
متن کاملPredicting directional hearing aid benefit for individual listeners.
The fitting of directional microphone hearing aids is becoming increasingly more routine, and this fitting option has proven to be a successful method to improve speech intelligibility in many noisy listening environments. Data suggest, however, that some hearing-impaired listeners receive significantly more directional benefit than others. It is of interest, therefore, to determine if directio...
متن کاملComparison of adaptive noise reduction algorithms in dual microphone hearing aids q
In this paper, a physical and perceptual evaluation of two adaptive noise reduction algorithms for dual-microphone hearing aids are described. This is the first comparison between a fixed directional microphone on the one hand, and an adaptive directional microphone and an adaptive beamformer on the other hand, all implemented in the same digital hearing aid. The adaptive directional microphone...
متن کاملEffect of signal-to-noise ratio on directional microphone benefit and preference.
This study examined speech intelligibility and preferences for omnidirectional and directional microphone hearing aid processing across a range of signal-to-noise ratios (SNRs). A primary motivation for the study was to determine whether SNR might be used to represent distance between talker and listener in automatic directionality algorithms based on scene analysis. Participants were current h...
متن کاملشکلدهی وفقی و هوشمند پرتو در آرایههای میکروفونی Ad-hoc با استفاده از خوشهبندی و رتبهبندی میکروفونها
Considering the existence of a many speech degradation factors, speech enhancement has become an important topic in the field of speech processing. Beamforming is one of the well-known methods for improving the speech quality that is conventionally applied using regular (classical) microphone arrays. Due to the restrictions in the regular arrangement of microphones, in recent years there has be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American Academy of Audiology
دوره 24 10 شماره
صفحات -
تاریخ انتشار 2013