Fluorescence of tetraphenyl-butadiene in the vacuum ultraviolet.

نویسندگان

  • W M Burton
  • B A Powell
چکیده

Tetraphenyl-butadiene is a useful alternative to sodium salicylate as a fluorescent wavelength converter for detectors in the vacuum uv. Measurements of the fluorescence efficiency of TPB relative to sodium salicylate over the wavelength range 735-3160 A are presented, and the application of TPB coatings to image tube detectors is discussed. Over the entire wavelength range studied TPB had a higher fluorescent efficiency than sodium salicylate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fluorescence efficiencies of thin scintillating films in the extreme ultraviolet spectral region

Fluorescence efficiencies of the organic scintillators tetraphenyl butadiene (TPB), p-terphenyl (TPH), and diphenyl stilbene (DPS) are measured relative to sodium salicylate at incident wavelengths of 58.4 and 74.0 nm. Optimum thickness and dopant concentration are determined for maximum fluorescence yield in evaporated, sprayed, and doped plastic films. Measurements made with alpha (a) particl...

متن کامل

Toward quantitative prediction of molecular fluorescence quantum efficiency: role of duschinsky rotation.

It is a highly desirable but difficult task to predict the molecular fluorescence quantum efficiency from first principles. The molecule in the excited state can undergo spontaneous radiation, conversion of electronic energy to nuclear motion, or chemical reaction. For relatively large molecules, it is impossible to obtain the full potential energy surfaces for the ground state and the excited ...

متن کامل

Tetraphenyl Butadiene Emanation and Bulk Fluorescence from Wavelength Shifting Coatings in Liquid Argon

We study the stability of three types of popularly employed TPB coatings under immersion in liquid argon. TPB emanation from each coating is quantified by fluorescence assay of molecular seive filter material after a prolonged soak time. Two of the coatings are shown to emanate a detectable concentration of TPB into argon over a 24 hour period, which corresponds to tens of parts per billion in ...

متن کامل

Organic matter from biofilter nitrification by high performance size exclusion chromatography and fluorescence excitation-emission matrix

A combination of high performance size exclusion chromatography with organic carbon detector and ultraviolet detector coupled with peak-fitting technique and fluorescence excitation-emission matrix spectrometry applied fluorescence regional integration method was conducted to determine the characteristics of organic matter during nitrification. The batch scale of bionet nitrification without or...

متن کامل

In vitro study of drug-protein interaction using electronic absorption, fluorescence, and circular dichroism spectroscopy

In the near future, design of a new generation of drugs targeting proteins will be required. Considering the complex bond between the drug and protein, the structure and stability of the target protein should be considered. So far, a series of in vitro investigations have been conducted with the aim of predicting drug-biological medium interactions. In these studies, use of spectroscopic method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 12 1  شماره 

صفحات  -

تاریخ انتشار 1973