A Polarization Control System for Intensity-Resolved Guided Mode Resonance Sensors
نویسندگان
چکیده
In this study, a polarization-control setup for intensity-resolved guided mode resonance sensors is proposed and demonstrated experimentally. The experimental results are in good agreement with the simulation data based on rigorous coupled wave approach calculations. The proposed intensity-resolved measurement setup transfers polarization ellipses, which are produced from guided mode resonance to a linear polarization state under a buffer solution condition, and then suppresses the signals to dark using a polarization-control set. Hence, any changes in the refractive index results in an increase in the intensity signals. Furthermore, no wavelength-resolved or angular-resolved measurement is needed in this scheme. According to the experimental results, a wide linear detection range of 0.014 refractive index units is achieved and the limit of detection is 1.62E-4 RIU.
منابع مشابه
Comparing signal amplification of thiocyanated Gold nanoparticles in the presence of different ions
Detecting is the most important section in all kinds of sensors. In this regard, the amplification of surface plasmon resonance intensity of gold colloids nanoparticles (GNPs) was studied in the presence of several ions. GNPs were synthesized and then capped by thiocyanate and characterized via DLS and TEM image. In the next step the effect of different concentrations of ions such as iron, copp...
متن کاملComparing signal amplification of thiocyanated Gold nanoparticles in the presence of different ions
Detecting is the most important section in all kinds of sensors. In this regard, the amplification of surface plasmon resonance intensity of gold colloids nanoparticles (GNPs) was studied in the presence of several ions. GNPs were synthesized and then capped by thiocyanate and characterized via DLS and TEM image. In the next step the effect of different concentrations of ions such as iron, copp...
متن کاملResonant Photonic Biosensors with Polarization-Based Multiparametric Discrimination in Each Channel
In this paper, we describe guided-mode resonance biochemical sensor technology. We briefly discuss sensor fabrication and show measured binding dynamics for example biomaterials in use in our laboratories. We then turn our attention to a particularly powerful attribute of this technology not possessed by competing methods. This attribute is the facile generation of multiple resonance peaks at a...
متن کاملTuning the transmission lineshape of a photonic crystal slab guided-resonance mode by polarization control.
We demonstrate a system consisting of a two-dimensional photonic crystal slab and two polarizers which has a tunable transmission lineshape. The lineshape can be tuned from a symmetric Lorentzian to a highly asymmetric Fano lineshape by rotating the output polarizer. We use temporal coupled mode theory to explain the measurement results. The theory also predicts tunable phase shift and group de...
متن کاملGenerating and Manipulating High Quality Factors of Fano Resonance in Nanoring Resonator by Stacking a Half Nanoring
We demonstrate the existence of Fano resonance spectral response in a system of nanoscale plasmonic resonant ring stacked by means of a half nanoring. Our proposed scheme exploits the stacked method under normal incidence to excite the subradiant mode. The nanostructure, which utilizes the combination of Fano resonance and polarization-resolved, has a new rotation mode and high tunability, prov...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2014