In Vivo Evaluation of Cervical Stiffness Evolution during Induced Ripening Using Shear Wave Elastography, Histology and 2 Photon Excitation Microscopy: Insight from an Animal Model

نویسندگان

  • Laura Peralta
  • Eve Mourier
  • Christophe Richard
  • Gilles Charpigny
  • Thibaut Larcher
  • Dora Aït-Belkacem
  • Naveen K. Balla
  • Sophie Brasselet
  • Mickael Tanter
  • Marie Muller
  • Pascale Chavatte-Palmer
  • Irene Georgakoudi
چکیده

Prematurity affects 11% of the births and is the main cause of infant mortality. On the opposite case, the failure of induction of parturition in the case of delayed spontaneous birth is associated with fetal suffering. Both conditions are associated with precocious and/or delayed cervical ripening. Quantitative and objective information about the temporal evolution of the cervical ripening may provide a complementary method to identify cases at risk of preterm delivery and to assess the likelihood of successful induction of labour. In this study, the cervical stiffness was measured in vivo in pregnant sheep by using Shear Wave Elastography (SWE). This technique assesses the stiffness of tissue through the measurement of shear waves speed (SWS). In the present study, 9 pregnant ewes were used. Cervical ripening was induced at 127 days of pregnancy (term: 145 days) by dexamethasone injection in 5 animals, while 4 animals were used as control. Elastographic images of the cervix were obtained by two independent operators every 4 hours during 24 hours after injection to monitor the cervical maturation induced by the dexamethasone. Based on the measurements of SWS during vaginal ultrasound examination, the stiffness in the second ring of the cervix was quantified over a circular region of interest of 5 mm diameter. SWS was found to decrease significantly in the first 4-8 hours after dexamethasone compared to controls, which was associated with cervical ripening induced by dexamethasone (from 1.779 m/s ± 0.548 m/s, p < 0.0005, to 1.291 m/s ± 0.516 m/s, p < 0.000). Consequently a drop in the cervical elasticity was quantified too (from 9.5 kPa ± 0.9 kPa, p < 0.0005, to 5.0 kPa ± 0.8 kPa, p < 0.000). Moreover, SWE measurements were highly reproducible between both operators at all times. Cervical ripening induced by dexamethasone was confirmed by the significant increase in maternal plasma Prostaglandin E2 (PGE2), as evidenced by the assay of its metabolite PGEM. Histological analyses and two-photon excitation microscopy, combining both Second Harmonic Generation (SHG) and Two-photon Fluorescence microscopy (2PF) contrasts, were used to investigate, at the microscopic scale, the structure of cervical tissue. Results show that both collagen and 2PF-active fibrillar structures could be closely related to the mechanical properties of cervical tissue that are perceptible in elastography. In conclusion, SWE may be a valuable method to objectively quantify the cervical stiffness and as a complementary diagnostic tool for preterm birth and for labour induction success.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Directional Filtering for Multiple-Driver Magnetic Resonance Elastography Data

D. S. Lake, A. Manduca, Y. Mariappan, R. L. Ehman Mayo Clinic College of Medicine, Rochester, MN, United States Introduction Magnetic resonance elastography (MRE) is a phase contrast based MRI imaging technique that can directly visualize and quantitatively measure propagating acoustic strain waves in tissue-like materials subjected to harmonic mechanical excitation [1]. The data acquired allow...

متن کامل

Differential Diagnosis of Parotid Gland Tumors: Role of Shear Wave Elastography

AIM To create a predictive score for the discrimination between benign and malignant parotid tumors using elastographic parameters and to compare its sensitivity and specificity with standard ultrasound. METHODS A total of 124 patients with parotid gland lesions for whom surgery was planned were examined using conventional ultrasound, Doppler examination, and shear wave elastography. Results ...

متن کامل

Evaluation of the diagnostic function of shear wave elastography in the differentiation of malignant and benign breast masses and its relationship with histological factors

Background: Shear wave elastography (SWE) estimates the stiffness of a mass based on the velocity of shear wave propagation by sound waves. Due to higher cell density and angiogenesis, malignant masses have higher stiffness than benign ones. Methods: The present study was a prospective study and was performed on patients who were referred to Ahvaz Golestan Hospital with breast mass during Marc...

متن کامل

Changes in shear wave speed pre- and post-induction of labor: a feasibility study.

OBJECTIVE To explore the feasibility of using shear wave speed (SWS) estimates to detect differences in cervical softening pre- and post-ripening in women undergoing induction of labor. METHODS Subjects at 37-41 weeks' gestation undergoing cervical ripening before induction of labor were recruited (n = 20). Examinations, performed prior to administration of misoprostol and 4 h later included ...

متن کامل

Assessment of Kidney Stiffness in a Swine Model of Renal Arterial Stenosis with 7-D MR Elastography

Introduction: MR Elastography (MRE) is an MRI-based technique for quantitatively assessing the mechanical properties of soft tissues by visualizing propagating shear waves in tissues (1). Ideally, the MRE acquisition would involve obtaining displacement data for 3 dimensions in space, 3 cyclic displacement directions (x, y, and z) at each point in space, and at multiple time points in the wave ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015