Alterations in normal canine platelets during storage in EDTA anticoagulated blood.
نویسندگان
چکیده
Flow cytometric detection of platelet surface-associated IgG (PSAIgG) can be used to determine whether immunologic factors are contributing to thrombocytopenia in dogs. In vitro alterations in platelet activation and morphology, however, could impact the results of this test. The purpose of this study was to determine whether the PSAIgG test for immune-mediated thrombocytopenia was valid on whole blood in EDTA anticoagulant after 24-72 hours of storage, and to characterize other alterations in canine platelets that could impact immunologic testing. Platelets were harvested and analyzed immediately after blood collection and after 24, 48, and 72 hours of storage at 4 degrees C. Spontaneous and thrombin-induced changes in the following platelet parameters were evaluated using flow cytometric techniques: PSAIgG, platelet microparticle formation, membrane expression of P-selectin and glycoprotein CD61, exogenous IgG binding, surface-exposed phosphatidylserine, and fibrinogen binding. The amount of PSAIgG increased 6- to 9-fold in stored samples compared with fresh samples. Platelet microparticle formation was spontaneous in stored samples and increased significantly over time. Membrane phosphatidylserine, P-selectin, and fibrinogen binding were not altered by storage, indicating that platelet activation was minimal in stored samples. Although storage decreased the percentage of platelets positive for CD61 by 8- to 10-fold compared with fresh samples, activation by high-dose thrombin partially restored the percentage of CD61-positive platelets in 24-hour-old samples. In conclusion, even though platelets stored in EDTA for up to 72 hours remain in a resting state, aged platelets have an increased tendency to form microparticles and have increased surface IgG and decreased surface CD61, which may contribute to false-positive results for tests of immune-mediated thrombocytopenia.
منابع مشابه
Evaluation of reticulated platelets in dogs with breed-related thrombocytopenia.
The aim of this study was to evaluate the percentage of reticulated platelets in healthy dogs with breed-related thrombocytopenia. Seventy two dogs, clinically healthy, were enrolled in the study. Blood was collected from the patients and anticoagulated with tripotassium ethylenediaminetetraacetic acid (K3-EDTA) and sodium citrate. Platelet count was obtained by an impedance haematology analyse...
متن کاملUse of theophylline in the investigation of pseudothrombocytopenia induced by edetic acid (EDTA-2K).
In automated cell counting of edetic acid (EDTA-2K) anticoagulated blood, thrombocytopenia is occasionally seen which bears no relation to any underlying disease. In this study a heparin and soluble theophylline mixture was used to measure accurately platelet numbers in patients with such pseudothrombocytopenia. In four normal volunteers, a theophylline concentration of more than 7 mg/ml produc...
متن کاملTransient appearance of EDTA-dependent pseudothrombocytopenia in a postoperative patient with sepsis
RATIONALE Ethylenediaminetetraacetic acid-dependent pseudothrombocytopenia (EDTA-PTCP) is a rare phenomenon characterized by spuriously low platelet counts when EDTA reacts with harvested blood. However, to the best of our knowledge, only two cases involving EDTA-PTCP in postoperative patients with sepsis have been reported. Here, we describe a case of EDTA-PTCP that appeared transiently in a p...
متن کاملPseudothrombocytopenia: manifestation of a new type of platelet agglutinin.
Spuriously low electronic platelet counts heparin, oxalate, or citrate. Agglutination were obtained on blood collected in EDTA in the presence of EDTA was not inhibited from six patients. Platelet numbers on by heparin, a-tocopherol, or N-ethylmaleblood smears and electronic counts perimide, but was inhibitied by excess EDTA formed on blood collected in other antior divalent cation. The aggluti...
متن کاملEffects of pre-analytical handling on selected canine hematological parameters evaluated by automatic analyzer
To assess the effects of pre-analytical handling (storage time and temperature) on selected hematological parameters, whole blood samples were collected in EDTA coated tubes from each of 30 clinically normal male adult beagle dogs. Each sample was separated in 2 aliquots, of which one was stored in ambient temperature (25 ˚C) and the other one was refrigerated (2 to 4 ˚C). Complete blood counts...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Veterinary clinical pathology
دوره 30 3 شماره
صفحات -
تاریخ انتشار 2001