Ultra-fast x-ray tomography for multi-phase flow interface dynamic studies
نویسندگان
چکیده
Use of X-ray CT (Computer Tomography) system has been extended from medical fields to a variety of industrial applications [1, 2]. Among them is the visualization of multi-dimensional void distribution of two-phase flow in tubes. Mitsutake et al. [3] and Morooka et al. [4] used medical X-ray CT scanners modified for void fraction measurement within rod bundles. The results were comparable with their predictions based on three-fluid model. Recently Tiseanu et al. applied cone beam tomography to bubbly flow in a vertical pipe and obtained sharper void peaks near the wall than previously reported [5]. Cone beam tomography is a 3D visualization technique and allowed them to collect multi-slice data in vertical direction within the same amount of scanning time as 2D systems. Gamma-ray is another form of generating high energy photons. Kumar et al. built a tomography system based on Cs-137 gamma ray source for void distribution measurement of a bubble column [6]. Although gamma ray sources eliminate the beam-hardening effect, low photon flux results in long scanning time. However, these systems are not applicable to dynamic interface detection of multi-phase flow because of low time resolution compared to transition time of interfaces. To visualize dynamic interfaces in multi-phase flow, time-resolved X-ray CT scanners have been developed by Hori and Akai [7], Hori et al. [8], and Misawa et al. [9] (Fig. 1). Scanning time of these systems is reduced by an order of two compared to existing ones. In pursuit of time resolution, however, spatial resolution is sacrificed due to less numbers of detector elements and views. The present paper describes the concept of fast scanning capability, hardware development, and measurement results of gas-liquid two-phase flow in a vertical pipe. Finally, to evaluate the measurement capability of the fast X-ray CT, the wiremesh sensor [10] was installed in the flow loop and both systems were operated for the same two-phase flow simultaneously. The results showed that the time series of cross section averaged void fraction agreed to each other for slug flow at large void fraction, but that the wire-mesh sensor was suitable for bubbly flow at low void fraction. From the comparison of the time series data, coerced deformation of slug bubble interface was suggested for the wire-mesh sensor.
منابع مشابه
Ultra Fast Electron Beam X-ray Computed Tomography for Two-phase Flow Measurement
Electron beam X-ray CT is a new technique for a fast measurement of multiphase flows with frame rates of 1000 images per second and more. It gives, in principle, quantitatively accurate images of the flow at high spatial resolution and it is non-intrusive since moderately radiation absorbing vessel walls can be penetrated by X-rays. However, on the road to a technical realisation of such a tech...
متن کاملHigh-speed swept source optical coherence Doppler tomography for deep brain microvascular imaging
Noninvasive microvascular imaging using optical coherence Doppler tomography (ODT) has shown great promise in brain studies; however, high-speed microcirculatory imaging in deep brain remains an open quest. A high-speed 1.3 μm swept-source ODT (SS-ODT) system is reported which was based on a 200 kHz vertical-cavity-surface-emitting laser. Phase errors induced by sweep-trigger desynchronization ...
متن کاملStudy of Two Phase Fluid Flow in Water Wet Reservoir Rocks by Using X-Ray In situ Saturation Monitoring
Displacement of oil and water in porous media of reservoir rocks is described by relative permeability curves, which are important input data for reservoir performance simulation and drive mechanism studies. Many core studies, such as multiphase relative permeability, capillary pressure and saturation exponent determination, depend on the volume fractions of multiphase flui...
متن کاملSimulation of Strap-On Boosters Separation in the Atmosphere
A numerical dynamic-aerodynamic interface for simulating the separation dynamics of constrained strap-on boosters jettisoned in the atmosphere is presented. A 6-DOF multi body dynamic solver ،using Constraint Force Equation Methodology is coupled with a numerical time dependent Euler flow solver. An automatic dynamic mesh updating procedure is employed using smoothing and l...
متن کاملStatus of the Ultra Fast Tomography Experiments Control at Anka
X-ray imaging permits to spatially resolve the 2D and 3D structure in materials and organisms, which is crucial for the understanding of their properties. Additional temporal resolution of structure evolution gives access to dynamics of processes and allows to understand functionality of devices and organisms with the goal to optimize technological processes. Such time-resolved dynamic analysis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -