Estimation errors of single dipole model applied to twin dipole activity: Computer simulation study

نویسندگان

  • T. Imada
  • T. Mashiko
  • H. Sekine
چکیده

Various methods have been proposed to solve magnetoencephalographic inverse problems although the problem itself is ill-posed and in principle infinite number of solutions are possible. Among them, the simplest method is the single dipole in a spherical head model, which has been practically used in a lot of papers to get the dipoles activated by the sensory and cognitive tasks. However, if the number of active locations in the brain is more than one, for example two closely located dipoles, this simplest single dipole solution brings an error in location and moment. This error seems to be larger when the distance of the two dipoles is smaller, when the dipole current orientations are parallel or antiparallel, and when the dipole current strengths are equal. Lütkenhöner discussed the separability of two dipoles [1]. In his paper, by simulating localization of a single dipole from the magnetic fields produced by two dipoles with various relationships including the distances and moments, he showed the separability of two dipoles in terms of necessity of introducing multiple dipole solution. In his simulation, he employed all channels of the 296-channel planar type whole-head virtual measurement system to localize a single dipole from the magnetic fields produced by two dipoles. However, if we localize a single dipole using several local channels of a whole-head measurement system that detected the magnetic fields produced by two dipoles, we are able to localize two separated dipoles under some conditions, namely when the two dipoles have some relationships of distance and moment. This is often observed when localizing the auditory N100m dipoles in the left and right hemispheres. Moreover, this localization with several locally selected channels is employed in most of experiments using a partial-head measurement system. Those who are using the partial-head measurement system to record the magnetic fields are implicitly selecting the local channels when they place the channel array over some part of the head for the measurement. When localizing multiple dipole activity by a single dipole method, this local-channel selection method has an advantage over the all-channel selection method. We can get more precise localization of the first dipole by selecting local channels that receive stronger magnetic signals from the first dipole and weaker signals from the second dipole as shown in Fig. 1.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Skull Inhomogeneities on Eeg Localization Accuracy

| The accuracy of the head model aaects on the solutions of the EEG inverse problems. If a simple three-sphere model and standard conductivity values for brain, skull and scalp regions are used, signifact errors may occur. One of the most sensitive head model parameters is the conductivity of the skull. A realistic three-dimensional nite-element model provides a method to study the eeect of inh...

متن کامل

Equivalent Dipole Sources Localization using Cortical Dipole Layer Imaging and Independent Component Analysis

We developed a new estimation method for equivalent dipole sources inside the brain. We have solved an inverse problem to estimate an equivalent dipole-layer distribution from the scalp electroencephalogram using spatio-temporal inverse filters. We estimated the position and moment of equivalent dipole sources from dipole layer distributions and separated each dipole layer distribution using in...

متن کامل

Design, Simulation and implementation of active dual-band dipole antenna using a series stub

In this paper, a new method for designing an active dual-band dipole antenna is proposed. The operating frequencies of the proposed antenna are 150 and 450 MHz that are usually used in military applications. Using a series stub is the main idea in the proposed dual-band antenna, where it makes an independent resonance frequency higher than the main resonance frequency of a conventional dipole. ...

متن کامل

EFFECTS OF TEMPERATURE AND PERCENTAGE OF ORGANIC MODIFIER ON RETENTION AND SELECTIVITY IN RP-HPLC USING SOLVATION PARAMETER MODEL

Effects of temperature and percentage of organic modifier were studied on retention and selectivity in RP-HPLC using solvation parameter model. The system constants were determined by multiple linear regression analysis from experimental values in the retention factor for a group of different solutes with known descriptors by computer using the program SPSS/PC. The experimental results showed t...

متن کامل

High-Resolution Cortical Dipole Imaging Using Spatial Inverse Filter Based on Filtering Property

Cortical dipole imaging has been developed to visualize brain electrical activity in high spatial resolution. It is necessary to solve an inverse problem to estimate the cortical dipole distribution from the scalp potentials. In the present study, the accuracy of cortical dipole imaging was improved by focusing on filtering property of the spatial inverse filter. We proposed an inverse filter t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001