CLINICAL SCIENCE Visual performance after interface haemorrhage during laser in situ keratomileusis

نویسندگان

  • R B Vajpayee
  • J S Titiyal
  • R M Pandey
چکیده

Aim: To study the visual performance in eyes with interface haemorrhage during laser assisted in situ keratomileusis (LASIK). Methods: Case records of 20 patients, who had bleeding from the limbal vessels in one eye during LASIK (group 1) and uncomplicated surgery in the fellow eye (group 2) were studied. The parameters evaluated were uncorrected visual acuity (UCVA) best corrected visual acuity (BCVA), spherical equivalent of refraction (SEQ), contrast sensitivity, and glare acuity preoperatively and at 1, 3, and 6 months postoperatively. Results: The mean preoperative SEQ in group 1 and 2 eyes was −5.79 (2.3) D and −5.27 (1.68) D, respectively. The mean decimal UCVA at 6 months after LASIK in group 1 and 2 eyes were 0.6 (0.2) and 1.0 respectively (p<0.001). The mean decimal BCVA at 1 week after LASIK in group 1 and 2 eyes were 0.89 (0.04) and 1.0 respectively (p<0.05). However, all eyes had a BCVA of 6/6 at 1, 3, and 6 months after LASIK. The mean contrast sensitivity values preoperatively in group 1 and 2 eyes were 161.3 (8.7) and 172 (68.2) respectively. There was a significant decrease in group 1 at 6 months (102 (60.5) (p<0.01)) compared to group 2. The decimal glare acuity preoperatively in group 1 and 2 eyes was 0.95 (0.11) and 0.89 (0.12), respectively. It decreased significantly in group 1 (0.7) (0.1 (p<0.01)) compared to group 2 at the 6 month follow up. Conclusion: Occurrence of intraoperative interface haemorrhage may affect the visual performance following LASIK surgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Visual performance after interface haemorrhage during laser in situ keratomileusis.

AIM To study the visual performance in eyes with interface haemorrhage during laser assisted in situ keratomileusis (LASIK). METHODS Case records of 20 patients, who had bleeding from the limbal vessels in one eye during LASIK (group 1) and uncomplicated surgery in the fellow eye (group 2) were studied. The parameters evaluated were uncorrected visual acuity (UCVA) best corrected visual acuit...

متن کامل

In vivo corneal confocal microscopy comparison of intralase femtosecond laser and mechanical microkeratome for laser in situ keratomileusis.

PURPOSE To assess and compare corneal modifications induced by IntraLase PulsionFS femtosecond laser and mechanical microkeratome Hansatome for laser in situ keratomileusis (LASIK) using the new-generation Heidelberg Retina Tomograph II (HRT II)/Rostock Cornea Module confocal microscope. METHODS In this case-control study, 24 eyes of 12 patients were examined with the HRT II in the follow-up ...

متن کامل

[Excimer laser in situ keratomileusis for severe ametropia after penetrating keratoplasty].

OBJECTIVE To evaluate the effects of excimer laser in situ keratomileusis in correcting severe myopia and astigmatism after penetrating keratoplasty. METHODS Excimer laser in situ keratomileusis was performed on ten eyes of ten patients to correct high ametropia in cases having previously undergone penetrating keratoplasty. RESULTS After surgery, all grafts remained clear and no corneal gra...

متن کامل

Central necrotic lamellar inflammation after laser in situ keratomileusis.

PURPOSE To report four cases of corneal interface complications that occurred after excimer laser in situ keratomileusis (LASIK). METHODS Four eyes of three patients underwent technically uneventful LASIK. RESULTS One day after LASIK, patients presented with severe pain, blurred vision, conjunctival infection, and diffuse opacity at the interface. Two days after LASIK, significant features ...

متن کامل

Vitreoretinal surgery for bilateral macular holes after laser-assisted in situ keratomileusis for the correction of myopia: a case report

UNLABELLED INTRODUCTION Laser-assisted in situ keratomileusis surgery may induce postoperative changes in the vitreomacular interface due to the mechanical stretch of the vitreous produced by the suction ring and the shock waves generated by the excimer laser and, subsequently, may provoke macular hole formation. CASE PRESENTATION A 53-year-old Spanish woman who had undergone a laser-assis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003