Mapping the pore size distribution of a glass microcapillary array phantom using d-PFG MRI
نویسندگان
چکیده
phantom using d-PFG MRI D. Benjamini M. E. Komlosh , P. J. Basser , U. Nevo STBB, PPITS, NICHD, NIH, Bethesda, MD; Department of Biomedical Engineering, The Iby and Aladar Fleischman Faculty of Engineering, Tel-Aviv University, Tel-Aviv, Israel. CNRM, USUHS, Bethesda, MD. Introduction: Noninvasive characterization of porous media is critical to many scientific and technical fields. Estimation of an empirical pore size distribution (PSD) has been demonstrated with single pulsed-filed gradient (s-PFG) NMR in conjunction with solving an inverse linear problem. In this case the solution depends on the degree of linear independence (degree of correlation between the different independent variables) of the matrix that describes the set of linear equations. As the degree of multicollinearity rises, the solution becomes more ill-conditioned. Recently this linear approach was extended to include a second dimension in the parameter space using a double pulsed-field gradient (d-PFG) experiment. This 2-D method was shown to reduce multicollinearity and thus improve the stability and reliability of the estimated empirical PSD. Previously, this 2-D NMR method was performed on calibrated microcapillary PSD phantoms, resulting in accurate size distribution estimation. Here we present the first MRI implementation of this 2-D method, and report the successful estimation of the PSD map using a well-characterized phantom. Methods: The PSD phantom is a glass capillary array (GCA) consisting of 3 different 2.5, 5, and 13.7 μm inner radii water-filled microcapillary wafers. d-PFG MRI experiments were performed on a 7T vertical-bore Bruker AVANCE III MR microimager. The acquisition parameters were: δ= 1.65ms, Δ=45ms, tm=0, 8 diffusion gradients (G = 0-605 mTm), 10 angles (φ = 0–π), TR=5s, TE= 7.75ms and spatial resolution = 0.242 X 0.242 X 1 mm. A total of 80 acquisitions were sufficient to obtain an accurate PSD in each voxel. The data was then fit to the 2-D linear PSD model. Results: A sagittal proton density MRI of the phantom is presented in Fig. 1A. Different waferpacks with different sizes are indicated, and the region of interest (ROI) for the PSD estimation is marked in blue. The estimated PSD is shown in Fig. 1B. The theoretical radii were verified by fitting the signal to the corresponding ROIs. The theoretical volumetric fractions were calculated from proton density MRI. Each theoretical distribution (blue) is known and presented on top of the estimated distribution (red). No regularization process or assumptions on the parametric form of the PSD are used. The obtained radii and their fractions are in very good agreement with the theory.
منابع مشابه
Pore diameter mapping using double pulsed-field gradient MRI and its validation using a novel glass capillary array phantom.
Double pulsed-field gradient (d-PFG) MRI can provide quantitative maps of microstructural quantities and features within porous media and tissues. We propose and describe a novel MRI phantom, consisting of wafers of highly ordered glass capillary arrays (GCA), and its use to validate and calibrate a d-PFG MRI method to measure and map the local pore diameter. Specifically, we employ d-PFG Spin-...
متن کاملNonparametric pore size distribution using d-PFG: comparison to s-PFG and migration to MRI.
Here we present the successful translation of a pore size distribution (PSD) estimation method from NMR to MRI. This approach is validated using a well-characterized MRI phantom consisting of stacked glass capillary arrays (GCA) having different diameters. By employing a double pulsed-field gradient (d-PFG) MRI sequence, this method overcomes several important theoretical and experimental limit...
متن کاملNovel anisotropic MRI diffusion phantom
Diffusion MRI (DMRI) comprises a growing list of methods, and with that the need for a reliable and robust MRI phantom with which one can calibrate and validate them. In this study we developed a novel anisotropic diffusion MRI phantom and demonstrated its applicability by producing fractional anisotropy (FA) maps derived from DTI and average pore diameter maps using double Pulsed Field Gradien...
متن کاملP27 Calibrating d-PFG Filtered MRI Using a Novel Anisotropic Diffusion Phantom
Diffusion Phantom Michal Komlosh 1, Evren Ozarslan 1, Martin Lizak 1, Ferenc Horkay 1, Peter Basser 1 1 National Institute of Health Introduction: Diffusion MRI methods can provide valuable microstructural in formation about tissues and porous media within an imaging volume [1-3], how ever, calibrating them is problematic owing to the lack of suitable anisotropic diffusion MRI phantoms. Here ...
متن کاملAnisotropic phantom to calibrate high-q diffusion MRI methods.
A silicon oil-filled glass capillary array is proposed as an anisotropic diffusion MRI phantom. Together with a computational/theoretical pipeline these provide a gold standard for calibrating and validating high-q diffusion MRI experiments. The phantom was used to test high angular resolution diffusion imaging (HARDI) and double pulsed-field gradient (d-PFG) MRI acquisition schemes. MRI-based ...
متن کاملذخیره در منابع من