7 Themes for guiding situated ergonomic assessments of medical devices: a case study of an inpatient glucometer.

نویسندگان

  • Dominic Furniss
  • Paolo Masci
  • Paul Curzon
  • Astrid Mayer
  • Ann Blandford
چکیده

There is relatively little guidance on the situated ergonomic assessment of medical devices, and few case studies that detail this type of evaluation. This paper reports results of a detailed case study that focuses on the design and use of a modern blood glucose meter on an oncology ward. We spent approximately 150 h in-situ, over 11 days and 4 nights, performing observations and interviews with users. This was complemented by interviews with two staff with oversight and management responsibility related to the device. We identified 19 issues with the design and use of this device. These issues were grouped into 7 themes which can help guide the situated study of medical devices: usability, knowledge gaps and mental models, workarounds, wider tasks and equipment, the patient, connection between services, and policy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Exploring medical device design and use through layers of Distributed Cognition: How a glucometer is coupled with its context

Medical devices are becoming more interconnected and complex, and are increasingly supported by fragmented organizational systems, e.g. through different processes, committees, supporting staff and training regimes. Distributed Cognition has been proposed as a framework for understanding the design and use of medical devices. However, it is not clear that it has the analytic apparatus to suppor...

متن کامل

A Comparative Study of Blood Glucose Measurements Using Glucometer Readings and the Standard Method in the Diagnosis of Neonatal Hypoglycemia

Background: Hypoglycemia is one of the most common neonatal disorders, associated with severe complications. There has been a great deal of controversy regarding the definition and screening of hypoglycemia. Therefore, in this study, we aimed to determine a cut-off value for blood glucose level in glucometer readings. Methods: This cross-sectional study was conducted on 238 newborns at risk of ...

متن کامل

مقایسه قدرت دستگاه گلوکومتر Accu-chek با Elite در تشخیص دیابت با استفاده از خونریزی متعاقب Probing

Abstract Background: Recent studies have assessed the validity of glucometer devices in estimating the glucose level of gingival blood during routine periodontal examination (Bleeding On Probing). The purpose of this study was to evaluate whether blood oozing from gingival tissues during routine periodontal examination can be used for determining g...

متن کامل

Survey of role of didactic interventional Ergonomic-Safety program on Workers’ productivity (Case-series study of electrical assembling industry)

Introduction: Occupational health is one of the important issues that can affect productivity and economic development of an organization. This study aimed to determine the effect of didactic interventional Ergonomic-Safety program on workers’ productivity of an assembling industry. Methods and Materials: This interventional study was conducted on 54 workers of assembling part of an electronic...

متن کامل

Halal Brand Is an Effective Solution for the Development of Medical Tourism: A Case Study of Hospital Hotel

Background and Objectives: Halal branding covers a wide range of economic activities including pharmaceuticals, cosmetics, health, textiles, clothing, leather, financial services, banking and tourism. Among the various forms of tourism, medical tourism has grown rapidly due to its competitive advantages. Therefore, the purpose of this study is to investigate halal branding as a strategy to deve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Applied ergonomics

دوره 45 6  شماره 

صفحات  -

تاریخ انتشار 2014