Measurement of intracompartmental pressure with use of a new electronic transducer-tipped catheter system.

نویسندگان

  • C Willy
  • H Gerngross
  • J Sterk
چکیده

Laboratory and clinical tests were carried out to determine the clinical usefulness, validity, and safety of a new self-calibrating, battery-powered monitoring system for the measurement of intramuscular pressure with use of an electronic transducer-tipped catheter. The eight probes accurately recorded applied pressures ranging from zero to 160 millimeters of mercury (zero to 21.33 kilopascals). The system registered little temperature-induced drift (maximum, 1.25 millimeters of mercury [0.17 kilopascal]) between dry room temperature and 40 degrees Celsius. There were also minimum variations (range, -0.14 to 0.81 millimeter of mercury [0.02 to 0.11 kilopascal]) in the pressures recorded during a twenty-four-hour period. The resting pressure in the tibialis anterior muscle of twenty volunteers who had normal limbs was a mean (and standard deviation) of 13.1+/-8.3 millimeters of mercury (1.75+/-1.11 kilopascals). There was a good correlation between externally applied pressures (zero, twenty, forty, sixty, eighty, and 100 millimeters of mercury [zero, 2.67, 5.33, 8.00, 10.66, and 13.33 kilopascals] applied with use of antishock trousers) and the pressures measured in the tibialis anterior muscle of four volunteers (r = 0.997 to 0.999). The injection of sterile saline solution into the tibialis anterior muscle of a volunteer and the use of high-frequency recording during muscular activity showed a high degree of responsiveness and sensitivity to changes in intramuscular pressure. We also prospectively evaluated the clinical usefulness of the system and found it to be easy to assemble, calibrate, and use. Thus, this reusable, electronic transducer-tipped catheter system, which is based on a noninfusion technique, is simple, minimally traumatic, and highly precise. It is free of hydrostatic pressure artifacts and provides dynamic responses to changes in intramuscular pressure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous ambulatory pulmonary artery pressure monitoring. A new method using a transducer tipped catheter and a simple recording system.

A transducer tipped catheter and simple recording system were used for the continuous measurement of ambulatory pulmonary artery pressure. The pulmonary artery pressure was recorded on a miniaturised tape recorder and replayed via an optical writer. Pulmonary arterial systolic and diastolic pressures can be analysed on a beat to beat basis. Continuous ambulatory monitoring was performed for a t...

متن کامل

The relationship between intracompartment pressure with symptoms of compartment syndrome and the level of creatine phosphokinase in limb trauma

Background: Acute compartment syndrome is considered a debilitating complication of limb trauma. Early detection of this compartment syndrome helps us in the early initiation of treatment which will result in preventing its subsequent complications reported in these cases. Methods: This research was an analytical cross-sectional study. Patients with direct trauma to extremities, who were refer...

متن کامل

تخمین فشار متوسط شریانی توسط پایش تهاجمی فشار شریانی با مانومتر

Background: Direct monitoring of arterial pressure using a transducer system is not affordable in most operating rooms and ICU wards in Iran. It is, however, possible to use an aneroid manometer instead, but it is not standardized yet, nor studied enough and its measurements may not be interpretable. Methods: To study the correlation of the arterial pressure readings between a manometer and a ...

متن کامل

Targeting Microvascular Pericytes in Angiogenic Vessels of Prostate Cancer PRINCIPAL INVESTIGATOR:

A novel procedure using a polyurethane transducer-tipped catheter (Millar) is described that allows reliable measurement of interstitial fluid pressure (IFP) in cancer tissues. Before and after each use, the transducer is calibrated at 37-C by a water column. After calibration, the transducer is passed through the lumen of a surgical needle. The sensor is kept in the lumen of the needle during ...

متن کامل

Using Experimental Modal Analysis Principles to Evaluate the Dynamics of Catheter Transducer System in Invasive-Pressure Measurements

The main objective of this paper is to employ basic modal testing principles in order to assess the dynamic behavior of fluid filled catheter in invasive pressure measurements. This type of dynamic measurement is particularly suitable in biomedical engineering applications, where accurate blood pressure readings are required in order to assess the patient real condition. The measurement procedu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 81 2  شماره 

صفحات  -

تاریخ انتشار 1999