Implantation of the biodegradable polymer biolimus-eluting stent in patients with high SYNTAX score is associated with decreased cardiac mortality compared to a permanent polymer sirolimus-eluting stent: two year follow-up results from the "all-comers" LEADERS trial.

نویسندگان

  • Joanna J Wykrzykowska
  • Scot Garg
  • Yoshinobu Onuma
  • Ton de Vries
  • Marie-Angele Morel
  • Gerrit-Anne van Es
  • Pawel Buszman
  • Axel Linke
  • Thomas Ischinger
  • Volker Klauss
  • Roberto Corti
  • Franz Eberli
  • William Wijns
  • Marie-Claude Morice
  • Carlo Di Mario
  • Robert-Jan van Geuns
  • Peter Juni
  • Stephan Windecker
  • Patrick W Serruys
چکیده

BACKGROUND The SYNTAX score (SXscore) has been shown to be an effective predictor of clinical outcomes in patients undergoing percutaneous coronary intervention (PCI). METHODS AND RESULTS The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the "all-comers" LEADERS trial (patients post-surgical revascularisation were excluded). Post hoc analysis was performed by stratifying clinical outcomes at two-year follow-up, according to one of three SXscore tertiles: SXlow ≤8 (n=464), 816 (n=461). At two-year follow-up the rate of major adverse cardiovascular events was 18.4%, 12.0% and 9.4% in the SXhigh, SXmid, and SXlow tertile, respectively (HR 1.45; CI 1.21-1.74; p<0.01). There was a significantly higher rate of cardiac death in patients in the highest SXscore tertile (7% SXhigh versus 2.4% SXmid versus 1.8% SXlow; HR 2.22; CI 1.5-3.27; p<0.001). Within the SXhigh tertile the rate of cardiac death was significantly lower in patients treated with the biolimus-eluting stent compared with the sirolimus-eluting stent (4.7% versus 9.6%, HR 0.48; CI 0.23-0.99; p=0.046). CONCLUSIONS The SXscore when applied to an "all-comers" patient population allows for prospective risk stratification of patients undergoing PCI up to two years follow-up. In addition, the SXscore appears to separate the performance of devices in high risk patient groups.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The three year follow-up of the randomised "all-comers" trial of a biodegradable polymer biolimus-eluting stent versus permanent polymer sirolimus-eluting stent (LEADERS).

AIMS The current study reports clinical outcomes at three year follow-up of the LEADERS clinical trial which was the first all-comers trial comparing a new generation biodegradable polymer biolimus drug-eluting stent (BES) with the first generation permanent polymer sirolimus-eluting stent (SES). METHODS AND RESULTS One thousand seven hundred and seven patients were randomised to unrestricted...

متن کامل

Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): a randomised non-inferiority trial.

BACKGROUND Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer-coated sirolimus-eluting stent in a population-based setting. METHODS This randomised, ...

متن کامل

Comparison of biolimus eluted from an erodible stent coating with bare metal stents in acute ST-elevation myocardial infarction (COMFORTABLE AMI trial): rationale and design.

AIMS Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled drug release have been identified as a potential trigger for these late adverse events and this has l...

متن کامل

Five-year outcomes of chronic total occlusion treatment with a biolimus A9-eluting biodegradable polymer stent versus a sirolimus-eluting permanent polymer stent in the LEADERS all-comers trial.

BACKGROUND Few data are available on long-term follow-up of drug-eluting stents in the treatment of chronic total occlusion (CTO). The LEADERS CTO sub-study compared the long-term results in CTO and non-CTO lesions of a Biolimus A9™-eluting stent (BES) with a sirolimus-eluting stent (SES). METHODS Among 1,707 patients enrolled in the prospective, multi-center, all-comers LEADERS trial, 81 wit...

متن کامل

2-year clinical follow-up from the randomized comparison of biolimus-eluting stents with biodegradable polymer and sirolimus-eluting stents with durable polymer in routine clinical practice.

OBJECTIVES This study sought to investigate safety and efficacy of biolimus-eluting stents (BES) with biodegradable polymer as compared with sirolimus-eluting stents (SES) with durable polymer through 2 years of follow-up. BACKGROUND BES with a biodegradable polymer provide similar efficacy and safety as SES with a durable polymer at 9 months. Clinical outcomes beyond the period of biodegrada...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology

دوره 7 5  شماره 

صفحات  -

تاریخ انتشار 2011