Influence of the Transducer Acoustic Power on Focal Location of the Beam

نویسندگان

  • Seyed Ahmad Reza Dibaji
  • Rupak K Banerjee
چکیده

1 ABSTRACT The location of High Intensity Focused Ultrasound (HIFU) beam in a tissue medium is an important parameter in assessment of the thermal field as it influences the temperature rise in the tissue. Our hypothesis is that the location of the beam can be affected by the power of the transducer. HIFU procedure with 30s of sonication time was performed at different powers of transducer (5 to 60 W) as well as different initial locations of beam in a tissue mimicking material. Eight thermocouples were embedded at 4 different layers in a phantom to measure the temperature rise during HIFU procedure. An inverse method based on experimental data and optimization algorithm was used to find the actual location of beam based on the experimental data. Our experimental data showed that for a higher power (60 W) as compared to a lower power (5 W), the focal distance that the actual position of beam moves away from its initial location increased with the raise in power. Thus, beam location can change at different powers of transducer. Using inverse method we showed that there is a direct linear correlation (R = 0.95) between the transducer power and the distance that beam moves away from its initial location. Therefore, it is of great clinical importance to study the effects of transducer power on the location of HIFU beam in an attempt to minimize the damage to healthy cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی انکسار پرتوهای فراصوت در هایفوتراپی و بهینه سازی عمق کانونی مبدل فراصوت جهت افزایش دقت درمان

Background and purpose: Nowadays High-intensity focused ultrasound (HIFU) as non-ionizing radiation is used for cancer treatment. Ultrasound beams when crossing the border of two environments are refracted causing decrease in the beam focusing within a tumor. Also, it may induce damage to normal tissues. In this study, we evaluated the focal depth shift induced by ultrasonic beam refraction. ...

متن کامل

Numerical Study for Optimizing Parameters of High-Intensity Focused Ultrasound-Induced Thermal Field during Liver Tumor Ablation: HIFU Simulator

Introduction High intensity focused ultrasound (HIFU) is considered a noninvasive and effective technique for tumor ablation. Frequency and acoustic power are the most effective parameters for temperature distribution and the extent of tissue damage. The aim of this study was to optimize the operating transducer parameters such as frequency and input power in order to acquire suitable temperatu...

متن کامل

Experimental Verification of Acoustic Saturation

The maximum value of acoustic pressure within an ultrasonic beam is limited by acoustic saturation. The t oretical basis for acoustic saturation has been analyzed previously. In this work, a high-power pulse source is used to drive acoustic pressure levels from an ultrasonic beam to saturation. An automatic procedure determines the field’s beam axis using a calibrated Marconi PVDF hydrophone. T...

متن کامل

Power optimization of a piezoelectric-based energy harvesting cantilever beam using surrogate model

Energy harvesting is a conventional method to collect the dissipated energy of a system. In this paper, we investigate the optimal location of a piezoelectric element to harvest maximum power concerning different excitation frequencies of a vibrating cantilever beam. The cantilever beam oscillates by a concentrated sinusoidal tip force, and a piezoelectric patch is integrated on the beam to gen...

متن کامل

Numerical simulation of laser beam welding of Ti6Al4V sheet

This paper was aimed to report the 3D finite element analysis simulation of laser welding process of Ti6Al4V 1.7 mm sheets in butt joint in order to predict the temperature distribution, hardness, and weld geometry. The butt-joint welds were made using CO2 laser with the maximum power of 2.2 kW in the continuous wave mode. A part of the experimental work was carried out to verify the weld geome...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012