Power Quality Improvement Using Fuzzy Controlled Shunt Active Filter

نویسنده

  • V. Chandra Sekhar
چکیده

This paper proposes a new control method of three phase active power filterfor reducing the source current harmonics for nonlinear loads. The control strategy includes the dq transformations and hysteresis technique for current injection. Renewable energy source (solar energy) is used as a backup device for converter. Dc voltage deviations due to harmonic injections are tracked by using proportional + integral control and fuzzy logic controller. The proposed work is implemented on MATLAB simulation software.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pi, Fuzzy Logic Controlled Shunt Active Power Filter for Three-phase Four-wire Systems with Balanced, Unbalanced and Variable Loads

This paper presents a fuzzy logic, PI controlled shunt active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Shunt Active Power filter is able to operate in balanced, unbalanced and Variable load condi...

متن کامل

A Novel Approach for Enhancement of Power Quality by Reduction of Total Harmonic Disortion in Three Phase Four Wire System

This paper presents a fuzzy logic, PI, average current controlled shunt active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Shunt Active Power filter is able to operate in balanced, unbalanced and Va...

متن کامل

Fuzzy Logic Based Power Quality Improvement Using Shuntactive Filter

This paper describes a novel fuzzy logic controller for a three phase shunt active shunt filter for the power quality improvement. The Power Quality (PQ) problems in power distribution systems are not new but only recently the effects of these problems have gained public awareness. These non-linear loads are constructed by nonlinear devices in which the current is not proportional to the applie...

متن کامل

Robust Control of Shunt Active Power Filter Using Interval Type-2 Fuzzy Logic Controller for Power Quality Improvement

Original scientific paper It is well-known that shunt active power filter (SAPF) is widely used to reduce harmonic distortion and to compensate reactive power in electrical power systems. DC bus voltage control of SAPF is very important for excellent power quality. In the control of SAPF, DC bus voltage is controlled by conventional control methods such as PI and PID controllers. However, these...

متن کامل

Fuzzy Logic Controller Based THD Reduction in Non-Linear Load Using Shunt Active Filter

This paper deals with an indirect current controlled shunt active power filter (SAPF) for improving power quality by reactive power compensation and harmonic filtering. The presence of harmonics and reactive power in the power source because it will cause additional power losses and malfunctions. The proposed APF is based on a voltage source inverter (VSI). The VSI is controlled by two loops, t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017