Formaldehyde as Screen Printing Indoor Pollutant

نویسندگان

  • Jelena Kiurski
  • Ljubo Nedović
  • Ivana Oros
  • Jelena Krstić
  • Lidija Čomić
چکیده

The presence of formaldehyde in indoor air samples has been detected in five screen printing facilities of Novi Sad, Serbia. Air was sampled five times during one working week for each screen printing facility. The sampling was conducted continuously during 4 hours. The concentrations of formaldehyde were determined by UV-VIS spectrometry at 580 nm. The average concentrations of formaldehyde were in the range from 0.413 to 0.836 ppm. Comparison of the detected concentration levels with the permissible exposure limit of 0.75 ppm (the OSHA standard) and 0.016 (the NIOSH standard) indicated that the average formaldehyde concentration in facility 5 was 1.11 and 52.25 times higher than prescribed values, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The daily and seasonal variability in residential concentrations of aldehydes in two Canadian cities

Indoor air concentrations of formaldehyde, acetaldehyde and acrolein were measured in Halifax, Nova Scotia and Edmonton, Alberta. Seven consecutive 24-hr measurements were made in 50 non-smoking homes in winter and summer in each city. In addition, data on relative humidity, temperature, air exchange rates, housing characteristics and occupants’ activities were collected. Determinants of indoor...

متن کامل

Study of the removal difference in indoor particulate matter and volatile organic compounds through the application of plants

This study was conducted to evaluate the ability of plants to purify indoor air by observing the effective reduction rate among pollutant types of particulate matter (PM) and volatile organic compounds (VOCs). PM and four types of VOCs were measured in a new building that is less than three years old and under three different conditions: before applying the plant, after applying the plant, and ...

متن کامل

Bioconversion of airborne formaldehyde by immobilized formaldehyde dehydrogenase from the recombinant methylotrophic yeast Hansenula polymorpha

Formaldehyde (FA) is a very toxic pollutant. FA in indoor air has a negative effect on human health and should be removed by ventilation or by conversion to non-toxic products. The formaldehyde dehydrogenase (FdDH), a NADand glutathione-dependent enzyme from recombinant methylotrophic yeast Hansenula polymorpha, was tested for its ability to oxidize airborne FA. A continuous fluidized bed biore...

متن کامل

Relationship Between Indoor Air Pollutant Levels and Residential Environment in Children With Atopic Dermatitis

PURPOSE This study was aimed to investigate the relationship between indoor air pollutant levels and residential environment in children with atopic dermatitis (AD) living in Seoul. METHODS A total of 150 children with AD were included. Residential environment was assessed by questionnaires which were completed by their parents. To evaluate the level of exposure to the indoor air pollutants, ...

متن کامل

Formaldehyde in the Indoor Environment

s Service (CAS). In 1944, Walker published the first edition of his classic work Formaldehyde.1 Between 1900 and 1930, formaldehyde-based resins became important * Author for correspondence. Address: Fraunhofer-Wilhelm-Klauditz-Institut (WKI), Department of Material Analysis and Indoor Chemistry, Bienroder Weg 54 E, 38108 Braunschweig, Germany. Phone: +49-531-2155-350. Fax: +49-531-2155-905. E-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012