Exploring the limits of RF shimming for high-field MRI of the human head.

نویسندگان

  • Weihua Mao
  • Michael B Smith
  • Christopher M Collins
چکیده

Several methods have been proposed for overcoming the effects of radiofrequency (RF) magnetic field inhomogeneity in high-field MRI. Some of these methods rely at least in part on the ability to independently control magnitude and phase of different drives in either one multielement RF coil or in different RF coils in a transmit array. The adjustment of these drive magnitudes and phases alone to create uniform RF magnetic (B(1)) fields has been called RF shimming, and has certain limits at every frequency as dictated by possible solutions to Maxwell's equations. Here we use numerical calculations to explore the limits of RF shimming in the human head. We found that a 16-element array can effectively shim a single slice at frequencies up to 600 MHz and the whole brain at up to 300 MHz, while an 80-element array can shim the whole brain at up to 600 MHz.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Improvement in B1+ Homogeneity and Average Flip Angle Using Dual-Source Parallel RF Excitation for Cardiac MRI in Swine Hearts

Cardiac MRI may benefit from increased polarization at high magnetic field strength of 3 Tesla but is challenged by increased field inhomogeneity. Initial human studies have shown that the radiofrequency (RF) excitation field (B1+) used for signal excitation in the heart is both inhomogeneous and significantly lower than desired, potentially leading to image artifacts and biased quantitative me...

متن کامل

SAR and Temperature Evaluations for B1 Shimming at 7 tesla

Introduction In high field MRI, the increased interactions between the electromagnetic waves and the biological tissues may give rise to heat and thermal hazards. This is clearly apparent for multi-transmit array applications where the electromagnetic fields are heavily manipulated in the subject to be imaged. In this work we provide complete 3D predictions of the B1 + fields, MRI images, energ...

متن کامل

Efficient Optimal-Numerical-Analytical Computation: Segmented Spiral Coil at High Field

Introduction: RF field non-uniformities caused by shortened RF wavelengths in human tissue significantly affect the image quality, especially for high-field MRI [1]. Spiral coils [2, 3] have been put forth to improve field homogeneity. In addition, RF shimming based on a TEM coil [4] or an RF transmit array [5] is an efficient method to address such non-uniformities. In this work, we combine th...

متن کامل

Nuts & Bolts of Advanced Imaging: Theory and Demonstration for Coils, RF Shimming and SAR

Highlights:  At high frequency MRI operation and electrically large (≥ 7T head, ≥ 3T body), asymmetrical, inhomogeneous, and/or irregularly-shaped loading, integer multiples of phase-shifts and uniform amplitudes are not necessarily the ideal characteristics to impose on the voltages driving the transmit array/coil in order to obtain a homogeneous transmit (with safe electric field) and/or rec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 56 4  شماره 

صفحات  -

تاریخ انتشار 2006