Evidence for Two New Solution States of Ubiquitin by IMS–MS Analysis
نویسندگان
چکیده
Ion mobility spectrometry coupled with mass spectrometry (IMS-MS) is used to investigate the populations of different states for ubiquitin in water:methanol solutions. In these experiments, ubiquitin is electrosprayed from 20 water:methanol (100:0 to 5:95, pH = 2) solutions, ranging from native to denaturing conditions. With an increased percentage of methanol in solution, ubiquitin ions ([M + 7H](7+) to [M + 12H](12+)) show substantial variations in both charge state distributions and ion mobility distributions. Analysis of these data provides evidence for the existence of five ubiquitin states in solution: the native N state, favored in solutions of 100:0 to 70:30 water:methanol for the +7 and +8 charge states; the more helical A state and a new closely related A' state, favored in solutions of 70:30 to 5:95 water:methanol for the +9 to +12 charge states; the unfolded U state, populated in 40:60 to 5:95 water:methanol solutions for the +8 to +10 and +12 charge states; and a new low-abundance state termed the B state, observed for 100:0 to 70:30 water:methanol solutions in the +8 to +10 and +12 charge states. The relative abundances for different states in different solutions are determined. The analysis presented here provides insight into how solution structures evolve into anhydrous conformations and demonstrates the utility of IMS-MS methods as a means of characterizing populations of conformers for proteins in solution.
منابع مشابه
FOCUS: ADVANCING HIGH PERFORMANCE MASS SPECTROMETRY: RESEARCH ARTICLE Solution Dependence of the Collisional Activation of Ubiquitin [M + 7H] Ions
The solution dependence of gas-phase unfolding for ubiquitin [M + 7H] ions has been studied by ion mobility spectrometry-mass spectrometry (IMS-MS). Different acidic water:methanol solutions are used to favor the native (N), more helical (A), or unfolded (U) solution states of ubiquitin. Unfolding of gas-phase ubiquitin ions is achieved by collisional heating and newly formed structures are exa...
متن کاملEffects of Fe(II)/H2O2 oxidation on ubiquitin conformers measured by ion mobility-mass spectrometry.
Oxidative modifications can have significant effects on protein structure in solution. Here, the structures and stabilities of oxidized ubiquitin ions electrosprayed from an aqueous solution (pH 2) are studied by ion mobility spectrometry-mass spectrometry (IMS-MS). IMS-MS has proven to be a valuable technique to assess gas phase and in many cases, solution structures. Herein, in vitro oxidatio...
متن کاملTransitions between Elongated Conformations of Ubiquitin [M+11H]<sup>11+</sup> Enhance Hydrogen/Deuterium Exchange
’ INTRODUCTION Since the development of electrospray ionization for mass spectrometry (MS), several MS-based approaches have been developed for characterizing structures of gas-phase protein ions. These can be categorized as either chemical or physicalmethods. Chemical methods include: ion ion and ion molecule reactions, detection of noncovalent adducts, 9 and monitoring of hydrogen/deuterium (...
متن کاملCharacterizing the structures and folding of free proteins using 2-D gas-phase separations: observation of multiple unfolded conformers.
Understanding the 3-D structure and dynamics of proteins and other biological macromolecules in various environments is among the central challenges of chemistry. Electrospray ionization can often transfer ions from solution to gas phase with only limited structural distortion, allowing their profiling using mass spectrometry and other gas-phase approaches. Ion mobility spectrometry (IMS) can s...
متن کاملIMS-IMS and IMS-IMS-IMS/MS for separating peptide and protein fragment ions.
Multidimensional ion mobility spectrometry (IMS-IMS and IMS-IMS-IMS) techniques have been combined with mass spectrometry (MS) and investigated as a means of generating and separating peptide and protein fragment ions. When fragments are generated inside a drift tube and then dispersed by IMS prior to MS analysis, it is possible to observe many features that are not apparent from MS analysis al...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 118 شماره
صفحات -
تاریخ انتشار 2014