Methods for Testing and Rating the Performance of Heating and Air Conditioning Systems

ثبت نشده
چکیده

EPCA required NBS to develop test procedures for each product for the determination of estimated annual operating cost and at least one other useful measure of energy consumption likely to assist consumers in making purchasing decisions. An additional requirement of the law was that “any test procedures prescribed be reasonably designed to produce test results which reflect energy efficiency, energy use, or estimated annual operating cost during a representative average use cycle and not be unduly burdensome to conduct.” Beginning in 1975, NBS staff reviewed the test procedures already in use within the appliance and heating and cooling industry. By the early 1980s, test procedures were in place for all covered products. Throughout the development, NBS staff worked closely with industry representatives experienced in testing the equipment to obtain their review and recommendations, particularly on energy conservation innovations that were being considered for future products. This review found many test procedures that could be used with minor modifications and recommended them for adoption. The industry procedures that required little change were primarily for “white” appliances, those used for cooking, cleaning, refrigerating food, etc. For them, the performance and annual cost of operation were primarily dependent on the use schedule. Therefore, NBS adopted steady-state tests plus a calculation procedure assuming a specific daily operating schedule. In the case of residential heating and cooling systems, however, entirely new procedures had to be developed, as described in these publications [1,2]. At the time, steady-state tests were used in the industry for central heating and cooling equipment. However, the equipment cycled on and off frequently throughout most days. During the start-up and shut-down periods, most of the equipment experienced non-trivial energy losses or inefficiencies associated with warm-up, cool-down, and/or migration of refrigerant. In addition, the performance of this equipment was almost independent of the user (except for thermostat setting) and primarily dependent on the weather conditions. As a result, NBS staff developed new procedures for this type of equipment that included steady-state and cycling tests coupled with a calculation procedure that accounted for the changing weather conditions throughout the heating and cooling seasons. Kelly and Chi published the initial procedure for central furnaces and boilers in 1978 [1]. The testing required was simple, but the estimation of yearly performance was done through an elaborate calculation procedure. They found that the performance of furnaces and boilers under part-load, on-off operation could be described by a simple “time-constant” model, and that data required to determine the time-constant could be obtained during “warm-up” and “cool-down” periods before and after a steady-state test without extensive cycling tests. Based on the test data, five major loss terms were calculated and subtracted from 100 to obtain the value of the seasonal efficiency.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Designing Fuzzy Controller for Air Conditioning Systems in order to Save Energy Consumption and Provide Optimal Conditions in Closed Environments (Indoors)

Today air conditioning systems have been considered by all people as one of welfarerequirements in buildings and closed environments. Since a considerable part of energy lossoccurs in ordinary modern systems, new strategies and solutions are developed in the field inorder to save amount of energy consumption and observe environmental considerations. Fuzzycontrol is one of these methods which pr...

متن کامل

Design and operation optimization of an air conditioning system through simulation: an hour-by-hour simulation study

In the present research, performance validation of a Heating, Ventilation, and Air Conditioning (HVAC) system operating in a library building was conducted. The operating HVAC system was studied in terms of the provided indoor air conditions and energy consumption level. The fieldwork measurements showed that the HVAC system is not capable of providing the desired indoor air conditions based on...

متن کامل

Passive Energy Air-to-Water Heat Pipe Based Heat Exchanger and its Potential of Air Pre-cooling in Air Conditioning Systems for Iran Climate

Air pre-cooling equipment is normally being employed in air-conditioning systems for pre-cooling the ambient outdoor air to enhance the air-conditioning systems performance. In this study, the potential of a passive water-to-air heat pipe based heat exchanger (HPHEX) for air pre-cooling purpose in air-conditioning systems for the high cooling load demanding regions of Iran was investigated. To ...

متن کامل

Application of Solar Thermal Collectors to Improve the Energy Performance of the Fresh Air HVAC Systems

 In the preset study, the performance of a solar assisted heating, ventilation and air conditioning (HVAC) system in an operating theater building was studied. The yearly performances of the existing HVAC system and the system with the added solar collectors were simulated in terms of energy consumption and provided air conditions using a transient system simulation software (TRNSYS). In t...

متن کامل

Performance Study of a Solar Integrated Central Heating System of a Residential Building Using Trnsys- an Hourly Simulation Model (RESEARCH NOTE)

In this investigation, the performance of an existing heating system of a residential building incorporated with an array of solar thermal collectors was studied. For this purpose, transient systems simulation program model was assembled to estimate the hour-by-hour performance of the existing and the system equipped with the solar thermal collectors in terms of the provided space air condition...

متن کامل

ارزیابی کارایی سیستم تهویه مطبوع یک ساختمان اداری در شهر تهران

Introduction: One of the factors influencing on indoor air quality of the buildings is performance of HVAC (heating, ventilation, and air conditioning) systems. These systems supply clean and odorless air, with temperature, humidity, and air velocity within comfort ranges for the residents. The aim of this study was to evaluate performance HVAC system in an administrative building in Tehran. .M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001