Effect of in vitro hemolysis on chemical values for serum.

نویسندگان

  • J J Frank
  • E W Bermes
  • M J Bickel
  • B F Watkins
چکیده

Hemolysis in serum specimens is commonplace. This study examines the effect of hemolysis on results of selected chemical assays. Hemolysis was simulated by adding hemolysate to serum to give hemoglobin concentrations of 90 to 2800 mg/liter and a rating by technologists of 0 to 4 + hemolyzed. The effect of hemolysis on values for some serum constituents, particularly acid phosphatase and creatine kinase, was shown to be method dependent. Not unexpectedly, hemolysis most affects results for lactate dehydrogenase.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An in vitro Comparative study upon the Hemolytic, Thrombogenic, Coagulation parameters and Stability properties of the Hemiscorpiuslepturus Venom

Hemiscorpius lepturus belonging to Hemiscorpiidae family is the most venomous of all types of scorpion existing in south west of Iran causing hemoglobinuria and dermal lesions by envenomation. We compare the hemolytic pattern upon time in different domestic animals upon time according to their different sphingomyelin contents. In addition other in vitro hematologic parameters, platelet lysis, c...

متن کامل

DETERMINATION OF SERUM LIPOPROTEINS IN BETA-THALASSEMIA TRAIT AND THEIR RELATIONSHIP TO CHRONIC HEMOLYSIS

100 patients with beta-thalassemia trait, comprised of 55 men and 45 women, participated in a study to measure serum lipoproteins. The results were compared with the data obtained from 100 control subjects of the same age and sex. A significantly lower level of mean serum total cholesterol and LDL cholesterol, and a much higher level of HDL cholesterol were obtained in beta-thalassemia trai...

متن کامل

Characterization of complement activity in serum of the four sturgeon species, Acipenser stellatus, A. baeri, A. nudiventris and Huso huso (Chondrostei: Acipenseridae)

Serum complement is valuable tool in determining the health status of fish. This study was conducted to examine in vitro activity of serum complement as an indicator of innate immunity in four sturgeon species, Acipenser stellatus, A. baeri, A. nudiventris and Huso huso (Chondrostei: Acipenseridae). The Effects of different temperatures, concentrations and volumes of serum on alternative comple...

متن کامل

Hemoglobin interference from in vivo hemolysis.

Laboratory values for specimens from a case of intravascular hemolysis showed that hemoglobin was significantly increased and thus could interfere with the determination of other analytes. We studied this problem by adding increasing amounts of purified hemoglobin (to a maximum concentration of 19.3 mg/L) to aliquots of pooled serum samples. The hemoglobin significantly interfered with the dete...

متن کامل

Hemolysins in acquired hemolytic anemia; effect of pH on the activity in vitro of a serum hemolysin.

By J. V. DAdE, M.B., M.R.C.P. LONDON H YDROGEN ion concentration has a controlling effect upon many hemolytic systems, both simple and complex. Osbor& in 1934 reviewed the early literature on the effect of pH on the hemolysis by complement of corpuscles sensitized by hemolytic immune body. He found that the optimum reaction for the hemolysis of sheep corpuscles by guinea pig serum was about pH ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 11  شماره 

صفحات  -

تاریخ انتشار 1978