Comparison of the time required for removal of intraradicular cast posts using two Brazilian ultrasound devices.

نویسندگان

  • Manoel Brito
  • Janir Alves Soares
  • Suelleng Maria Cunha Santos
  • Carla Cristina Camilo
  • Gil Moreira
چکیده

The aim of this in vitro study was to compare the time required for removal of intraradicular cast posts cemented with zinc phosphate (ZF) or glass ionomer cement (GIC), using two Brazilian ultrasound devices (BUD). Seventy two human inferior premolars with single root canals were sectioned transversally at the cementoenamel junction. In each specimen, the root canal was endodontically treated, the post space was prepared to a depth of 9 mm and the canal was molded to obtain a post impression. After the casting procedures, the posts were randomly distributed into 2 groups (n = 36) according to the luting material used: G1 - ZF and G2 - GIC. The tooth and luted post set was then embedded in an acrylic resin block. The groups were then divided into 3 subgroups (n = 12) according to the ultrasound device used: A - Enac (Osada Electric, Japan), used as a control group; B - Profi II Ceramic (Dabi Atlante, Brazil) and C - Jet Sonic Satelec (Gnatus, Brazil). The posts were submitted to the vibration process with maximum power set on all surrounding surfaces. Time of application was recorded with a chronometer until complete post dislodgment, and the data were analyzed by the ANOVA test (p < 0.05). The averages required for post removal in G1 and G2 were respectively 41.42 and 92.03 seconds, with significant statistical difference (p = 0.001). No statistical difference was observed among the three ultrasound devices (p = 0.088), and the BUD presented a performance similar to that of the international gold standard device (Enac). Moreover, the type of luting agent had a greater influence on the time required for post removal than the origin of the ultrasonic unit.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficacy of ultrasound in removal of intraradicular posts using different techniques.

The efficacy of ultrasound in removing cast metal posts was evaluated in this in vitro study using one or two ultrasound units and ultrasonic vibration for various lengths of time. The crowns of 30 healthy maxillary canines were removed, the roots were embedded in acrylic resin blocks, and the root canals were treated endodontically. The canals were prepared and their impressions were taken wit...

متن کامل

Comparison of different ultrasonic vibration modes for post removal.

This in vitro study compared different ultrasonic vibration modes for intraradicular cast post removal. The crowns of 24 maxillary canines were removed, the roots were embedded in acrylic resin blocks, and the canals were treated endodontically. The post holes were prepared and root canal impressions were taken with self-cured resin acrylic. After casting, the posts were cemented with zinc phos...

متن کامل

Influence of Luting Agents on Time Required for Cast Post Removal by Ultrasound: an in Vitro Study

OBJECTIVE This in vitro study evaluated the influence of luting agents on ultrasonic vibration time for intraradicular cast post removal. MATERIAL AND METHODS After endodontic treatment, 30 roots of extracted human canines were embedded in resin cylinders. The post-holes were prepared at 10 mm depth and their impressions were taken using autopolymerizing acrylic resin. After casting procedure...

متن کامل

Comparison of the effect of shoulder and contra bevel preparation on fracture resistance of teeth restored with cast posts

Comparison of the effect of shoulder and contra bevel preparation on fracture resistance of teeth restored with cast posts Dr. SA. Shayegh* - Dr. F. Gangy** *- Assistant Professor of Prosthodontics Dept. - Faculty of Dentistry – Shahed University of Medical Sciences. **- Dentist. Background and Aim: Studies concerning the effects of post-core design on fracture resistance of endodontically trea...

متن کامل

Comparison of dentinal crack incidence and of post removal time resulting from post removal by ultrasonic or mechanical force.

The purpose of this study was to compare the frequency of canal and intradentin cracks after intraradicular post removal using ultrasonic instrumentation or the Gonan post removal system. Sixty cadaver teeth were divided into 4 groups of 15 teeth each: group 1, ultrasonic removal; group 2, Gonan post removal system; group 3, cemented posts not removed; and group 4, no posts. Groups 1 and 2 were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Brazilian oral research

دوره 23 1  شماره 

صفحات  -

تاریخ انتشار 2009