Harmonization of the Volume of Interest Delineation among All Eleven Radiotherapy Centers in the North of France

نویسندگان

  • David Pasquier
  • Laurence Boutaud de la Combe-Chossiere
  • Damien Carlier
  • Franck Darloy
  • Anne Catherine Degrendel-Courtecuisse
  • Chantal Dufour
  • Mustapha Fares
  • Laurent Gilbeau
  • Xavier Liem
  • Philippe Martin
  • Pascal Meyer
  • Jean François Minne
  • Olimpia Olszyk
  • Hassan Rhliouch
  • Marc Tokarski
  • Chloé Viot
  • Bernard Castelain
  • Eric Lartigau
چکیده

BACKGROUND Inter-observer delineation variation has been detailed for many years in almost every tumor location. Inadequate delineation can impair the chance of cure and/or increase toxicity. The aim of our original work was to prospectively improve the homogeneity of delineation among all of the senior radiation oncologists in the Nord-Pas de Calais region, irrespective of the conditions of practice. METHODS All 11 centers were involved. The first studied cancer was prostate cancer. Three clinical cases were studied: a low-risk prostate cancer case (case 1), a high-risk prostate cancer case (pelvic nodes, case 2) and a case of post-operative biochemical elevated PSA (case 3). All of the involved physicians delineated characteristically the clinical target volume (CTV) and organs at risk. The volumes were compared using validated indexes: the volume ratio (VR), common and additional volumes (CV and AV), volume overlap (VO) and Dice similarity coefficient (DSC). A second delineation of the same three cases was performed after discussion of the slice results and the choice of shared guidelines to evaluate homogenization. A comparative analysis of the indexes before and after discussion was conducted using the Wilcoxon test for paired samples. A p-value less than 0.05 was considered to indicate statistical significance. RESULTS The indexes were not improved in case 1, for which the inter-observer agreement was considered good after the first comparison (DSC = 0.83 ± 0.06). In case 2, the second comparison showed homogenization of the CTV delineation with a significant improvement in CV (81.4 ± 11.7 vs. 88.6 ± 10.26, respectively, p = 0.048), VO (0.41 ± 0.09 vs. 0.47 ± 0.07, respectively; p = 0.009) and DSC (0.58 ± 0.09 vs. 0.63 ± 0.07, respectively; p = 0.0098). In case 3, VR and AV were significantly improved: VR: 1.71(± 0.6) vs. 1.34(± 0.46), respectively, p = 0.0034; AV: 46.58(± 14.50) vs. 38.08(± 15.10), respectively, p = 0.0024. DSC was not improved, but it was already superior to 0.6 in the first comparison. CONCLUSION Our prospective work showed that a collaborative discussion about clinical cases and the choice of shared guidelines within an established framework improved the homogeneity of CTV delineation among the senior radiation oncologists in our region.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of clinical target volume delineation using magnetic resonance spectroscopic imaging (MRSI) in 3D conformal radiotherapy of prostate cancer

Background: For the purpose of individual clinical target volume assessment in radiotherapy of prostate cancer, MRSI was used as a molecular imaging modality with MRI and CT images. Materials and Methods: The images of 20 prostate cancer patients were used in this study. The MR and MRSI images were registered with CT ones using non-rigid registration technique. The CT based planning (BP), CT/MR...

متن کامل

Differentiation of Edematous, Tumoral and Normal Areas of Brain Using Diffusion Tensor and Neurite Orientation Dispersion and Density Imaging

Background: Presurigical planning for glioma tumor resection and radiotherapy treatment require proper delineation of tumoral and peritumoral areas of brain. Diffusion tensor imaging (DTI) is the most common mathematical model applied for diffusion weighted MRI data. Neurite orientation dispersion and density imaging (NODDI) is another mathematical model for DWI data modeling.Objective: We stud...

متن کامل

Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters

Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...

متن کامل

Contribution of 68Ga-PSMA PET/CT to targeting volume delineation of prostate cancer treated with conformal radiation therapy: Which SUV threshold is appropriate?

Introduction: Prostate-specific membrane antigen (PSMA) has been demonstrated as a promising tool for specific imaging of prostate cancer (PCa) via positron emission tomography-computed tomography (PET/CT) scanning. Radiation treatment planning (RTP) based on 68Ga-PSMA PET/CT scanning can also lead to some decision modifications.  The specific goal o...

متن کامل

Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study

Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016