HPLC measurement of phenylalanine in plasma.
نویسندگان
چکیده
Measurement of phenylalanine in plasma is required for the diagnosis and subsequent dietary management of phenylketonuria (PKU). We have developed an isocratic high-performance liquid-chromatographic (HPLC) method, with ultraviolet detection. For this measurement 10 microL of plasma is needed, and the complete analysis can be done in less than 15 min. Interbatch coefficients of variation for human plasma samples (phenylalanine 136-1541 mumol/L) ranged between 2.2% and 4.4%. The method has a wide linear range (10-3500 mumol/L), and results (y) correlated well with those (x) of an ion-exchange chromatographic method (r = 0.996; y = 1.014 x - 11.9; n = 64, range 22-1823 mumol/L). Only standard HPLC equipment is needed and no specialized sample preparation or detection system is required. The procedure has proved robust and reliable in regular routine use.
منابع مشابه
Simple and sensitive high performance liquid chromatographic method for the simultaneous quantitation of the phenylalanine in human plasma
Phenylalanine (Phe) is the most reliable indicator for the diagnosis of phenylketonuria (PKU). The purpose of this study is to establish a reliable and quick method for the assignment of Phe in peripheral capillary blood from newborns and children by high performance liquid chromatography with ultraviolet detection (HPLC-UV). PKU is an inborn error of metabolism characterized by the inability o...
متن کاملHPLC measurement of phenylalanine by direct injection of plasma onto an internal-surface reversed-phase silica support.
Direct-injection analysis for phenylalanine in plasma by isocratic "high-performance" liquid chromatography (HPLC) is described. For chromatographic separation I use an internal-surface reversed-phase silica support. The method involves ultraviolet detection, requires as little as 10 microL of plasma (routinely 20 microL), and supplies results in less than 7.5 min from injection. The intra-batc...
متن کاملA New Potentiometric Sensor for Determination and Screening Phenylalanine in Blood Serum Based on Molecularly Imprinted Polymer
Methods routinely utilized for detection of phenylalanine in new-born blood consist of enzymatic assays, lacking sensitivity and HPLC assays which are expensive and time-consuming to conduct. We, here, report for the first time, the construction of a phenylalanine sensitive electrode, on the basis of a selective molecularly imprinted polymer, offering sensitivity, economy and ease of use for th...
متن کاملA New Potentiometric Sensor for Determination and Screening Phenylalanine in Blood Serum Based on Molecularly Imprinted Polymer
Methods routinely utilized for detection of phenylalanine in new-born blood consist of enzymatic assays, lacking sensitivity and HPLC assays which are expensive and time-consuming to conduct. We, here, report for the first time, the construction of a phenylalanine sensitive electrode, on the basis of a selective molecularly imprinted polymer, offering sensitivity, economy and ease of use for th...
متن کاملMolecular Diagnosis of Plasma Phenylalanine in Neonates with Phenylketonuria Disease Using Biological Sensors Based on Surface-Enhanced Raman Spectroscopy (SERS)
In this study, silver nanoparticles were chemically synthesized and deposited on glass substrates using a reducing agent of sucrose, at 50°C. Different characterizations including atomic force microscopy (AFM), field emission scanning electron microscopy (FESEM), and Raman spectroscopy were obtained to study silvery substrates. Then, the silvery substrates were used as the SERS substrates to de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 34 11 شماره
صفحات -