Perfusion index and plethysmographic variability index in patients with interscalene nerve catheters.

نویسندگان

  • Anne Sebastiani
  • Larissa Philippi
  • Stefan Boehme
  • Dorothea Closhen
  • Irene Schmidtmann
  • Anton Scherhag
  • Klaus Markstaller
  • Kristin Engelhard
  • Gunther Pestel
چکیده

BACKGROUND Interscalene nerve blocks provide adequate analgesia, but there are no objective criteria for early assessment of correct catheter placement. In the present study, pulse oximetry technology was used to evaluate changes in the perfusion index (PI) in both blocked and unblocked arms, and changes in the plethysmographic variability index (PVI) were evaluated once mechanical ventilation was instituted. METHODS The PI and PVI values were assessed using a Radical-7™ finger pulse oximetry device (Masimo Corp., Irvine, CA, USA) in both arms of 30 orthopedic patients who received an interscalene catheter at least 25 min before induction of general anesthesia. Data were evaluated at baseline, on application of local anesthetics; five, ten, and 15 min after onset of interscalene nerve blocks; after induction of general anesthesia; before and after a 500 mL colloid fluid challenge; and five minutes thereafter. RESULTS In the 25 patients with successful blocks, the difference between the PI values in the blocked arm and the PI values in the contralateral arm increased within five minutes of the application of the local anesthetics (P < 0.05) and increased progressively until 15 min. After induction of general anesthesia, the PI increased in the unblocked arm while it remained relatively constant in the blocked arm, thus reducing the difference in the PI. A fluid challenge resulted in a decrease in PVI values in both arms. CONCLUSION The perfusion index increases after successful interscalene nerve blockade and may be used as an indicator for successful block placement in awake patients. The PVI values before and after a fluid challenge can be useful to detect changes in preload, and this can be performed in both blocked and unblocked arms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Pulse Oximeter Plethysmographic Waveform Reflects Changes That Occur during the Respiratory Cycle

Many pulse oximetry technologies display a processed and filtered representation of the photoplethysmosgraphic waveform. Each manufacturer uses unique proprietary algorithms to calculate the waveform displayed on the pulse oximeter. Masimo has extracted and processed information from the waveform to create two physiologic indices, perfusion index (PI) and pleth variability index (PVI). PI is ca...

متن کامل

The Pulse Oximeter Plethysmographic Waveform Reflects Changes That Occur during the Respiratory Cycle

Many pulse oximetry technologies display a processed and filtered representation of the photoplethysmosgraphic waveform. Each manufacturer uses unique proprietary algorithms to calculate the waveform displayed on the pulse oximeter. Masimo has extracted and processed information from the waveform to create two physiologic indices, perfusion index (PI) and pleth variability index (PVI). PI is ca...

متن کامل

Non-invasive blood haemoglobin and plethysmographic variability index during brachial plexus block.

BACKGROUND Plethysmographic measurement of haemoglobin concentration ([Formula: see text]), pleth variability index (PVI), and perfusion index (PI) with the Radical-7 apparatus is growing in popularity. Previous studies have indicated that [Formula: see text] has poor precision, particularly when PI is low. We wanted to study the effects of a sympathetic block on these measurements. METHODS T...

متن کامل

Clinical investigation of plethysmographic variability index: A derivative index of pulse oximetry in anesthetized dogs

Paranjape, Vaidehi V. M.S., Purdue University, August 2014. Clinical Investigation of Plethysmographic Variability Index: A Derivative Index of Pulse Oximetry in Anesthetized Dogs. Major Professor: Jeff C. Ko. Plethysmographic Variability Index (PVI) is a derivative index of pulse oximetry that allows evaluating an individual's intravascular volume status. Perfusion Index (PI) represents the st...

متن کامل

The impact of intra-abdominal pressure on the stroke volume variation and plethysmographic variability index in patients undergoing laparoscopic cholecystectomy.

The purpose of the present study was to evaluate the effect of increasing intra-abdominal pressure (IAP) on stroke volume variation (SVV) and plethysmographic variability index (PVI) in patients undergoing laparoscopic cholecystectomy. PVI examined by Masimo Radical 7 pulse oximeter and SVV determined using FloTrac/Vigileo were monitored simultaneously in forty-five patients undergoing laparosc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Canadian journal of anaesthesia = Journal canadien d'anesthesie

دوره 59 12  شماره 

صفحات  -

تاریخ انتشار 2012