Immunochemical methods for measurement of transferrin in serum: effects of analytical errors and inappropriate reference intervals on diagnostic utility.

نویسندگان

  • Z L Bandi
  • I Schoen
  • D E Bee
چکیده

We estimated analytical errors of the Calbiochem, Kallestad, Hyland, Meloy, Helena, and Beckman immunochemical methods for serum transferrin. Intermethod biases were determined by analysis of the "Reference Preparation for Serum Proteins" of the College of American Pathologists and by analysis of 106 patients' serum samples. We judged the acceptability of errors by comparing confidence limits for total errors with 1/4 of the normal reference intervals. The transferrin status of each patient's sample was interpreted by comparing the result of each method with the normal reference interval claimed by the corresponding manufacturer. We found that the combined effects of medically unacceptable analytical errors and inappropriate normal intervals caused results of the tested methods not to be interchangeable. The Calbiochem method identified 61 serum samples (57%) as having abnormally high transferrin concentrations. In contrast, for the same specimen, with the Meloy method we found abnormally high transferrin concentrations for only two samples (1.8%).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Age Specific Reference Levels of Serum Prostate-Specific Antigen, Prostate Volume and Prostate Specific Antigen Density in Healthy Iranian Men

Background: It is relevant to highlight that there is not a precise and perfect report on either 95 percentile value (upper limit of normal range) or on appropriate reference intervals for serum PSA in Iranian population. Objective: To determine age-specific reference ranges for serum prostate-specific antigen (PSA) concentration and PSA density (PSAD) and prostate volumes in a population of he...

متن کامل

Qualitative and Quantitative Approaches for Determination of Hemolyzed Serum

Abstract Background and Objective: Prevention of medical laboratory errors is a major goal of quality control programs. Hemolyzed specimen is one of the common issues causing medical laboratory errors. Apart from the visual assessment, the measurement of serum hemoglobin concentration can be another method to evaluate the intensity of hemolysis. We aimed to assess hemolyzed serum s...

متن کامل

Effect of analytical factors on immunochemical reference limits for complement component C3 in serum of a reference pediatric population.

We evaluated analytical factors such as antibody specificity, standard materials, and methodology for the measurement of C3. Mancini-type radial immunodiffusion and immunonephelometry were shown to give comparable data if variables other than procedural variables are eliminated. The most significant analytical factors affecting the measurement were antiserum specificity and source of standard m...

متن کامل

Chemical and immunochemical measurement of total iron-binding capacity compared.

Radiometric, colorimetric, and two immunochemical methods for measuring total iron-binding capacity are compared. We evaluated the procedures on the basis of precision, applicability to a pediatric population, and accuracy as assessed by analytical recovery of purified transferrin. The immunoephelometric assay for transferrin provides significant advantages over the other methods examined.

متن کامل

Pediatric Reference Intervals for Transferrin Saturation in the CALIPER Cohort of Healthy Children and Adolescents

BACKGROUND Transferrin saturation reference intervals specific for age and sex have not been previously reported for the pediatric population. The reference values for transferrin saturation have been previously reported to be lower in children compared to adults, caused by a combination of low serum iron and high serum transferrin levels in children, warranting specific reference intervals. He...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 31 10  شماره 

صفحات  -

تاریخ انتشار 1985