Determination of serum or plasma glucose on the "AutoAnalyzer II" by use of the hexokinase reaction.

نویسندگان

  • G M Widdowson
  • J R Penton
چکیده

Manual procedures based on these reactions and involving the direct addition of serum to a single reagent are commonly used as emergency procedures in routine clinical chemistry laboratories of hospitals. We have adapted one of these methods, “Glucose 500-Pack” (Calbiochem, P.O. Box 12087, San Diego, Calif. 92772) to an automated method on the “AutoAnalyzer II” (Technicon Instruments Corp., Tarrytown, N.Y. 10591). The AutoAnalyzer II is well suited to automation of this method because the sample blank can be measured simultaneously. In addition, smaller manifold pump tubes can be used with the AutoAnalyzer II colorimeter than were necessary in the AutoAnalyzer “N” methodologies, thus permitting use of about half the reagent volume per sample suggested in the reagent manufacturer’s instructions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved manual and automated colorimetric determination of serum glucose, with use of hexokinase and glucose-6-phosphate dehydrogenase.

A previously reported assay for serum gluCose, in which hexokinase and glucose-6-phosphate dehydrogenase were used, was improved to replace the light-sensitive phenazine methosulfate with “diaphorase,” providing a one-reagent system. The assay system was automated for use with standard AutoAnalyzer equipment and evaluated at 40 and 60 samples per hour with a 2:1 sample-to-wash ratio. Sensitivit...

متن کامل

Interlaboratory comparison of enzymatic methods for serum glucose determination.

This report describes an interlaboratory comparison of enzymatic serum glucose methods as currently applied in several instrumental adaptations. Four spectrophotometric, hexokinase-based methods used with the Du Pont "aca," the Abbott "Bichromatic Analyzer," the Aminco "Rotochem," and the Technicon "AutoAnalyzer ll" were compared with glucose oxidase-based methods as used with the Beckman "Gluc...

متن کامل

Rate of Glucose Utilization by Blood Cells in Serum and Plasma Specimens With or Without Using Preservative

Objective: This study aims to estimate and compare the time-course change in blood glucose levels by blood cells in serum, and plasma with or without preservatives, which may reflect the rate of glucose utilization by blood cells. Method: This laboratory-based cross-sectional study was carried out using a blood specimen of 28 participants among which 14 were diagnosed with diabetes and 14 were...

متن کامل

Application of a new peroxide indicator reaction to the specific, automated determination of glucose with glucose oxidase.

We describe an automated, colorimetric determi. nationof glucose in biological fluids that combines the specificityof glucose oxidase and of a new peroxide indicator reaction. In the presence of peroxidase, 3-methyl-2-benzothiazoli none hydrazone oxidativelycouples with N,N-dimethylaniline to form a stable,intensely colored, water-soluble indamine dye, the concentration of which is proportional...

متن کامل

Opium Consumption Challenge and Diabetes Mellitus Control

OBJECTIVE: During recent years, opium consumption has increased among Iranian diabetic men. The belief that opium consumption can control or even eradicate DM is increasing. This study was conducted to compare the blood sugar, HbA1c, lipid profile and the frequency of diabetes complications in male type II diabetic patient with and without opium consumption. MATERIALS AND METHODS: Two hundred...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 18 3  شماره 

صفحات  -

تاریخ انتشار 1972