Comparison of dichromate and ethanol-chlorobenzene dosimeters in high dose radiation processing

نویسندگان

  • Bojana Šećerov
  • Goran Bačić
چکیده

Radiation processing in many areas, particularly in radiation sterilization, demands control of the absorbed dose. Many dosimeters have been proposed for the high-level dose range (region of 10 to 50 kGy). However, in addition to the required reproducibility, reliability or uncertainty (< 5%), it is desirable for radiation processing that the selected dosimetric system is easy to operate. One of those “easy-to-use” high dose dosimeters is the ethanol-chlorobenzene (ECB) dosimeter but only when the measurement of doses is done by oscillometric readout and not when high precision is needed which requires titration of chloride ions formed by irradiation [2]. The dichromate dosimeter is now a well known dosimetric system whose preparation is standardized [4]. It is used as a reference/transfer dosimeter by virtue of its excellent stability and reproducibility. Preparation and measurements can be characterized as “easy-touse”. Considering these characteristics, the dichromate dosimeter seems to be a good candidate for use in radiation processing as a routine as well as a reference/ transfer dosimeter. However, the dichromate dosimeter shows the irradiation temperature dependence which could present a problem in measurements of absorbed doses for varying conditions of irradiation in radiation processing. The irradiation temperature dependence was studied earlier [6], but the verification of consistency of those results in real conditions of irradiation in radiation processing needs further investigation. The present study investigates characteristics of both dosimeters, the ECB and dichromate dosimeter, Comparison of dichromate and ethanol-chlorobenzene dosimeters in high dose radiation processing Bojana Šećerov, Goran Bačić

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Obtained Results from Two Calibration Methods in MRI Brachytherapy Normoxic Polymer Gel Dosimetry

Introduction: Despite the fact that the clinical implementation of polymer gel dosimetry has been facilitated after the introduction of normoxic gels, there are still complications in its clinical routine use that are under investigation. In the current work, the feasibility of using a normoxic polymer gel dosimeter named MAGICA has been investigated for use in our clinical brachytherapy applic...

متن کامل

CCRI supplementary comparison of standards for absorbed dose to water in 60 Co gamma radiation at radiation processing dose levels

Six national standards for absorbed dose to water in Co gamma radiation at the dose levels used in radiation processing have been compared over the range from 5 to 30 kGy using the alanine dosimeters of the NIST and the NPL as the transfer dosimeters. The standards are in agreement at the level of around 0.5%, which is significantly smaller than the stated standard uncertainties. r 2006 Elsevie...

متن کامل

An investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy

Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...

متن کامل

Dose measurement outside of radiotherapy treatment field (Peripheral dose) using thermoluminesent dosimeters

Background: In radiation therapy, peripheral dose or the dose outside the radiotherapy field, is important when anatomical structures with very low dose tolerances are involved. One of these critical organs in pelvic irradiation is testis. The amount of radiation delivered to the testes in radiotherapy must be kept as small as possible, consistent with the limit dose of this organ. The threshol...

متن کامل

Dimethyl sulfoxide, diethyl fumarate solution for high dose dosimetry

Background: Dosimetry is a fundamental part of the radiation processing industry. Aqueous inorganic dosimeters have been used for gamma radiation dosimetry such as standard ferrous sulfate dosimeter. The purpose of this study was to investigate the effect of gamma radiation on the diethyl fumarate DEF in dimethyl sulfoxide DMSO solution and its possible use in chemical dosimetry. Materials and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008