Sample preparation followed by high performance liquid chromatographic (HPLC) analysis for monitoring muconic acid as a biomarker of occupational exposure to benzene.
نویسندگان
چکیده
Factors affecting solid phase extraction (SPE) of trans,trans-muconic acid (ttMA), as a benzene biomarker, including sample pH, sample concentration, sample volume, sample flow rate, washing solvent, elution solvent, and type of sorbent were evaluated. Extracted samples were determined by HPLC-UV (high performance liquid chromatography-ultraviolet). The analytical column was C18, UV wave length was 259 nm, and the mobile phase was H(2)O/methanol/acetic acid run at flow rate of 1 ml/min. A strong anion exchange silica cartridge was found successful in simplifying SPE. There was a significant difference between recoveries of ttMA when different factors were used (p < .001). An optimum recovery was obtained when sample pH was adjusted at 7. There was no significant difference when different sample concentrations were used (p > .05). The optimized method was then validated with 3 different pools of samples showing good reproducibility over 6 consecutive days and 6 within-day experiments.
منابع مشابه
Solid Phase Extraction for 1-Hydroxypyrene as a Biomarker of Occupational Exposure to PAHs Prior to High Performance Liquid Chromatography
Urinary 1-hydroxypyrene is frequently used as a major metabolite and biological indicator of the overall exposure to polycyclic aromatic hydrocarbons. In this study, solid phase extraction was appropriately conditioned with regard to sample pH, sample concentration, loading flow rate, elution solvent, washing solvent, sample volume and sorbent mass. Octadecyl silica cartridge (C<su...
متن کاملUrine trans,trans-muconic acid as a biomarker for benzene exposure in gas station attendants in Bangkok, Thailand.
The toxicity of benzene, a chemical used in many industrial processes, involves bone marrow depression and leukemogenesis and is associated with damage to multiple classes of hematopoietic cells and hematopoietic functions. Environmental exposure to benzene causes an increased body burden, which is reflected in several biomarkers, eg, urine trans,trans-muconic acid (ttMA). Associated with the i...
متن کامل[Assessment of urinary trans, trans-muconic acid as a biomarker of exposure to benzene].
OBJECTIVE To assess the use of trans, trans-muconic acid as a biomarker of occupational exposure to benzene. METHODS Trans, trans-muconic acid in urine samples of exposed (exposed group, n=36) and non-exposed (non-exposed group, n=116) workers to benzene. Urinary levels of trans, trans-muconic acid were quantified by high-performance liquid chromatography. The study sample consisted of subjec...
متن کاملHigh-performance liquid chromatography method for urinary trans,trans-muconic acid. Application to environmental exposure to benzene.
This report describes a specific and precise high-performance liquid chromatography (HPLC) method for the quantification of trans,trans-muconic acid in human urine. The procedure involved a highly efficient Bond-Elut SAX extraction with 20% acetic acid elution. The HPLC analysis used a sodium acetate/methanol mobile phase with a C18 reverse phase column and UV detection at 265 nm. The recovery,...
متن کاملبهینه سازی روش تغلیظ و تخلیص ترانس، ترانس - موکونیک اسید به عنوان شاخص بیولوژیکی بنزن در مواجهه های شغلی
In this study, parameters affecting on SPE of trance trance muconic acid (t,t-MA), including sample pH, sample concentration, sample volume, sample flow rate, washing solvent, elution solvent, and type of sorbent were evaluated. After sample preparation of muconic acid as urinary metabolite of benzene, it was determined by HPLC-UV. In chromatographic analysis, column was C18 (250 cm × 4.6 mm id...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- International journal of occupational safety and ergonomics : JOSE
دوره 11 4 شماره
صفحات -