Determination of lead by on-line solid phase extraction using a PTFE micro-column and flame atomic absorption spectrometry.
نویسندگان
چکیده
A rapid and sensitive time-based flow injection (FI) method for on-line preconcentration and determination of lead by flame atomic absorption spectrometry (FAAS), using polytetrafluoroethylene (PTFE) turnings as packing material in a micro-column, has been developed. The sample was mixed on-line with ammonium pyrrolidine dithiocarbamate (APDC) and the non-charged Pb(II)-PDC complex was absorbed quantitatively on the hydrophobic PTFE material, at a pH range 1.4-3.2. The preconcentrated complex was effectively eluted with isobutyl methyl ketone (IBMK) and introduced into the nebulizer-burner system. A nested coil (NC) is proposed for parking the eluate temporarily, in order to enable different elution and nebulization flow rates. With 180 s preconcentration time the sample frequency was 15 h(-1), and the enhancement factor was 330 at 13.0 ml min(-1) sample flow rate. The detection limit was c(L)=0.8 mug l(-1), the relative standard deviation (R.S.D.) 2.6% at the 30 mug l(-1) level and the calibration curve was linear over the concentration range 1.6-100 mug l(-1). The proposed method was evaluated by analyzing certified reference materials of water, sediments and fish tissue. Finally, it was applied successfully to the analysis of various environmental samples.
منابع مشابه
Application of Sulfur Nanoparticles as a Solid Phase Extraction Sorbent for the Preconcentration of Lead(II) and Palladium(II) in Environmental Samples Prior to Flame Atomic Absorption Spectrometry Determination
The application of sulfur nanoparticles as an efficient adsorbent for the solid-phase extraction and determination of the trace amounts of Pb and Pd ions was investigated in environmental samples using flame atomic absorption spectrometry. Effects of various parameters such as pH, flow rate of sample and eluent, type and concentration of eluent, sample volume, amount of adsorbent and interferin...
متن کاملDetermination of arsenic(III) by flow injection solid phase extraction coupled with on-line hydride generation atomic absorption spectrometry using a PTFE turnings-packed micro-column.
A novel flow injection (FI) solid phase extraction method for the determination of arsenic(III) at trace levels was developed, using on-line hydride generation atomic absorption spectrometry (HG-AAS). Selective determination of As(III) was achieved by on-line formation and retention of the pyrrolidine dithiocarbamate arsenic complex As(III)-PDC on the PTFE turnings which are packed in the preco...
متن کاملEvaluation of two different extraction techniques on determination of 〖Pb〗^(+2) contents of wastes of dye manufacturing industries
Extraction of trace amounts of toxic heavy metals from complicated environmental matrixes is a challenging task. The aim of this investigation is the comparison of the extraction efficiencies and other related experimental variables ( chemicals, effect of pH, potential interfering ions) on the determination of inorganic lead ( ) which is present in waste water of dye industries. Compared techn...
متن کاملSolid Phase Extraction of Ultra Trace Amounts of Ni2+ by Dimethylglyoxime (DMG) Immobilized on Column
A column of alumina modified with sodium dodecyl sulfate (SDS) and dimethylglyoxime (DMG) was prepared for the preconcentration of trace nickel from water samples for flame atomic absorption spectrometry (FAAS) determinations. Under optimized conditions (pH=7.0; flow rate: 20 mlmin-1) nickel was retained on the column. The nickel collected on the column was eluted with 5 mL of 1 M nitric ac...
متن کاملComparison of Modified Palladium Nanoparticles and Homemade Activated Carbon Derived from Medlar for Solid Phase Extraction of Metal Ions Prior to Their Flame Atomic Absorption Spectrometry Determination
This study focus on the preparation of two supports including activated carbon derived from medlar and Palladium nanoparticles loaded on activated carbon (Pd-NP-AC). Subsequently, both adsorbent modified with a novel Schiff base chelating agent and their potential applicability for determination of trace amounts of metal ions from aqueous solution has been investigated. The method is based on c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Talanta
دوره 57 5 شماره
صفحات -
تاریخ انتشار 2002