Development of Digital Myocardial Phantom to Evaluate Software for Gated SPECT

نویسندگان

  • Takeshi Murakami
  • Jun Hashimoto
  • Taeko Hara
  • Takashi Yamashita
  • Toshiki Kazama
  • Yutaka Imai
چکیده

Background: Real cardiac phantoms are often used to assess the performance of software for gated single-photon emission computed tomography(SPECT). However, these phantoms have disadvantages in that they are not very similar to actual hearts and setting a perfusion defect is not easy. To overcome these problems, we developed a digital myocardial phantom, named%Myo-Simu'. The aims of this study were to check its operation when being incorporated into gated SPECT software and to elucidate its usefulness to assess properties of software. Methods: Myo-Simu yields a simulated left ventricle(LV)approximated as a moving spheroid that preserves shape similarity during the cardiac cycle with a fixed total myocardial volume. Wall thickness, background activity, spatial resolution, statistical noise, and perfusion defects are incorporated into the phantom, and these conditions can be modified by changing the input parameters. We generated various types of hearts by changing the length of the short and long axes, patterns of perfusion defects, spatial resolution, and image noise. Generated SPECT images were applied to Quantitative Gated SPECT(QGS), Heart Function View, and EXINI Heart software to check the adaptability to gated SPECT analyses. We also evaluated the influences of wall thickness and spatial resolution on QGS analyses. Results: Myo-Simu successfully generated SPECT images of various geometries. These images can be applied to gated SPECT analyses without any problems in operation. In QGS, measured LV volumes changed greatly depending on wall thickness and spatial resolution. Conclusions: Myo-Simu is a feasible phantom for assessing gated SPECT software.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The value of the Gated 99mTc-MIBI SPECT in differentiation of fixed myocardial lesions [Persian]

Fixed myocardial defects in both stress and rest images, could be artifactual as a result of soft tissue attenuation. To increase specificity and identify the false positive results, we used gated technique to evaluate the wall motion and wall thickening as an index to differentiate real ischemic lesions from artifactual defects. 93 patients were studied. In 46 patients (48.8%) fixed perf...

متن کامل

Evaluation of the potential impact of reconstruction method on dyssynchrony parameters derived by phase analysis of gated-SPECT MPI: Comparison of two quantitative software

Introduction: Gated SPECT myocardial perfusion scanning has new capabilities in addition to its main applications such as left ventricular dyssynchrony using phase analysis. Phase analysis has been investigated through various software including Emory Cardiac Toolbox (ECTb) and Quantitative Gated SPECT (QGS). The aim of this study is to evaluate the effect of reconstruction par...

متن کامل

Nicorandil effect on myocardial perfusion in patients with slow coronary flow phenomenon assessment by gated myocardial perfusion SPECT

Introduction:Patients with the coronary slow flow phenomenon (SCF) frequently experience angina episodes. The purpose of this study was to determine efficacy of nicorandil in myocardial perfusion in patients with SCF. Methods: Twenty patients (50.85 ± 12.96 y) with SCF were studied.  We evaluate coronary slow flow according to protracted thrombolysis in m...

متن کامل

The role of oral dipyridamole stress gated SPECT in assessing the response of the left ventricle to stress: Re-evaluation of an old method

Introduction: We aimed to assess whether the vasodilator effect of oral dipyridamole on the left ventricular systolic function in patients with suspected CAD is different from that of intravenous (IV) dipyridamole using Tc-99m MIBI myocardial perfusion gated SPECT. Methods: Eighty-nine patients (17 M / 72 W; 61 ± 10 years) were enrolled in this study. The patients underwent a dipyridamole stre...

متن کامل

Evaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy

Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015