Evaluation of the effect of temperature on the tortional stiffness of active Austenitic and active Martensitic Nickel Titanium arch wires: An In-vitro study

نویسنده

  • Abhishek Bansal
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Effect of an Experimental Herbal versus Fluoridated Mouthwash on Frictional Resistance and Surface Roughness between Orthodontic Brackets and Two Types of Archwire: In Vitro Study

Introduction: The present study aimed to evaluate an experimental herbal mouthwash, as compared to sodium fluoride mouthwash on the frictional resistance and surface roughness between brackets and two rectangular archwire types. Methods: A total of 60 premolar׳s brackets engaged with 0.019×0.025 archwires made of stainless steel and nickel-titanium alloys were used in this study. The samples we...

متن کامل

A review of the requirements and hazards of toxic metals from orthodontic wires

Background: Orthodontics is a part of dentistry that includes preventive methods and correction of dental irregularities that need to be repositioned by functional and mechanical tools to provide an ideal occlusion and a beautiful face for patients. There are currently four metal arch wires used in orthodontic treatment: stainless steel alloy, cobalt-chromium alloy, nickel-titanium alloy, and b...

متن کامل

Effect of the Primary Microstructures during Training Producers on TWSME in NiTi Alloys (TECHNICAL NOTE)

The influence of the martensitic, martensitic+austenitic and austenitic structures in bending training on two-way shape memory effect (TWSME) in Ni-50.8 at %Ti and Ni-49.9 at %Ti alloys was studied. In addition of the primary structure, the effect of pre-strain, plastic strain, training cycle and training temperature on the TWSME was investigated. The prepared samples were trained in martensiti...

متن کامل

Effects of three different mouthwashes on the surface characteristics of nickel-titanium and Stainless steel archwires in orthodontics

Introduction: Patients are recommended regular using of mouthwashes to control dental caries or periodontal diseases since orthodontic treatment may have detrimental effects on the tooth structures. However, chemical agents may potentially damage metal components of orthodontic appliances. The aim of this study was to evaluate the influence of three mouthwashes on the surface characteristics of...

متن کامل

Ni-Ti orthodontic archwires at different temperatures

Orthodontic mechanotherapy encompasses the use of several archwires during speci c stages of treatment. Metallic orthodontic appliances consist of bands, arch wires, ligature wires, hooks, tubes, brackets, and springs are daily used in orthodontic practices for the correction of malocclusions in patients ( Oh et al. , 2004 ; Verstrynge et al. , 2006 ; Sabane et al. , 2009 ). One of the most im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014