Leads dislodged into the pulmonary vascular bed in patients with cardiac implantable electronic devices

نویسندگان

  • Maciej Polewczyk
  • Wojciech Jacheć
  • Aneta M. Polewczyk
  • Anna Polewczyk
  • Marek Czajkowski
  • Andrzej Kutarski
چکیده

INTRODUCTION Spontaneous lead dislodgement into the pulmonary circulation is a rare complication of permanent pacing with unproven harmfulness and an indication of controversial class for transvenous lead extraction (TLE). AIM To assess TLE safety in patients with leads dislodged into the pulmonary artery. MATERIAL AND METHODS A retrospective analysis of a 9-year-old database of transvenous lead extraction procedures comprising 1767 TLEs was carried out, including a group of 19 (1.1%) patients with leads dislodged into the pulmonary artery (LDPA). RESULTS Under univariate analysis the factors that increased the likelihood of the presence of an electrode in the pulmonary artery were mean lead dwelling time (increase of risk by 9% per year), total number of leads in the heart before TLE (increase of risk by 66% for one lead) and the number of abandoned leads (increase of risk by 119%). The presence of LDPA was associated with frequent occurrence of intracardiac lead abrasion (increase by 316%) and isolated lead-related infective endocarditis (LRIE) (increase by 500%). There were no statistically significant differences in clinical (p = 0.3), procedural (p = 0.94) or radiological (p = 0.31) success rates in compared (LDPA and non-LDPA) groups. Long-term mortality after TLE was comparable in both groups. CONCLUSIONS As the effectiveness and safety of TLE in patients with LDPA are comparable to those in standard TLE procedures, in our opinion, such patients should be considered TLE candidates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implantable Port Devices, Complications and outcome in Pediatric Cancer, a Retrospective Study

Abstract Background Peripheral blood vessels, due to availability are used for many years in cancer patients, however in patients with potentially harmful drugs to skin (vesicant drugs) or difficult accessibility to vessels, the use of implantable port (totally implantable venous access port-TIVAP)devices with central vascular access are important.  ...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

Lung lobectomy in a patient with an implantable left ventricular assist device.

Non-cardiac surgical procedures in patients with left ventricular assist devices (LVADs) pose a special challenge given the hemodynamic and hematologic considerations in these patients. During pulmonary procedures in patients with LVADs, special attention should be paid to hemodynamics because lung resection surgery requires a lateral decubitus position, single-lung ventilation and postoperativ...

متن کامل

Safety of magnetic resonance imaging in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices.

Magnetic resonance imaging (MRI) in patients with implanted cardiac prostheses and metallic cardiovascular electronic devices is sometimes a risky procedure. Thus MRI in these patients should be performed when it is the only examination able to help with the diagnosis. Moreover the diagnostic benefit must outweigh the risks. Coronary artery stents, prosthetic cardiac valves, metal sternal sutur...

متن کامل

Cardiac Implantable Electronic Device Safety during Magnetic Resonance Imaging

BACKGROUND AND OBJECTIVES Although magnetic resonance imaging (MRI) conditional cardiac implantable electronic devices (CIEDs) have become recently available, non-MRI conditional devices and the presence of epicardial and abandoned leads remain a contraindication for MRIs. SUBJECTS AND METHODS This was a single center retrospective study, evaluating the clinical outcomes and device parameter ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2016