Combination of Multicatheter Plus Stent or Balloon for Treatment of Complex Aneurysms.

نویسندگان

  • H J Jeon
  • B M Kim
  • D J Kim
  • K Y Park
  • J W Kim
  • D I Kim
چکیده

BACKGROUND AND PURPOSE Coiling of complex aneurysms is still difficult even with current adjuvant techniques. This study sought to evaluate the safety and effectiveness of a combination of multicatheter plus stent or balloon for the treatment of complex aneurysms. MATERIALS AND METHODS All complex aneurysms that underwent coiling with the combination technique were identified from prospectively maintained neurointerventional data bases. "Complex aneurysm" was defined as a wide-neck aneurysm with branch incorporation into or a deep lobulation of the sac. The clinical and angiographic outcomes were retrospectively analyzed. RESULTS Sixty-two complex aneurysms (12 ruptured, 50 unruptured) in 62 patients (mean age, 57 years; male/female ratio, 12:50) were treated with a combination technique by using a multicatheter plus stent (n = 42, 3 ruptured) or balloon (n = 20, 9 ruptured). Treatment-related morbidity (grade 3 hemiparesis) occurred in 1 patient (1.6%). Except for 1 patient who had treatment-related morbidity, none of the other patients with unruptured aneurysms developed new neurologic symptoms at discharge. Nine of the 12 patients with ruptured aneurysms had good outcomes (Glasgow Outcome Score, 4 or 5) at the latest follow-up (mean, 32 months; range, 6-72 months), and 1 patient died from an initial SAH. Posttreatment control angiograms revealed complete occlusion in 27, neck remnant in 34, and incomplete occlusion in 1 aneurysm. At least 1 follow-up catheter or MR angiogram was available in 80.6% (n = 50) (mean, 21 months; range, 6-65 months). There were 4 minor and 3 major recurrences (14.0%). CONCLUSIONS In this case series, the combination technique by using multicatheter plus stent or balloon seemed safe and effective for the treatment of complex aneurysms.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy

Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...

متن کامل

HyperForm balloon-assisted endovascular neck bypass technique to perform balloon or stent-assisted treatment of cerebral aneurysms.

We describe a technique to bypass aneurysm neck using the HyperForm balloon to perform balloon- or stent-assisted endovascular treatment of complex large or giant aneurysms with very wide neck in which other methods would fail to obtain an access distal to the aneurysm.

متن کامل

Transcirculation endovascular treatment of complex cerebral aneurysms: technical considerations and preliminary results.

BACKGROUND Unfavorable anatomy can preclude embolization of intracranial aneurysms. Transcirculation techniques, in which a catheter is navigated from one side of the brain to the other or from the anterior to the posterior circulation, are alternative pathways for primary or balloon- or stent-assisted coiling. OBJECTIVE We report the largest experience in coil embolization of aneurysms using...

متن کامل

Endovascular coil embolization of aneurysms with a branch incorporated into the sac.

BACKGROUND AND PURPOSE Because of the concern for occlusion of the incorporated branch artery, an aneurysm with a branch incorporated into the sac has been regarded as a contraindication for coiling. The aim of this study is to evaluate the feasibility, techniques, and clinical and angiographic outcomes of coiling for aneurysms with a branch incorporated into the sac. MATERIALS AND METHODS Th...

متن کامل

Stent placement for the treatment of complex internal carotid bifurcation aneurysms: a review of 16 cases.

AIM Stent placements for the treatment of complex internal carotid bifurcation aneurysms are not well documented yet. In this article, we reported a series of 16 such cases to evaluate the feasibility, safety and effectiveness of stent placement for these particular lesions. MATERIAL AND METHODS Between June 2001 and August 2011, 16 patients with 16 ICA bifurcation aneurysms were treated by s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 37 2  شماره 

صفحات  -

تاریخ انتشار 2016