BACKGROUND Ozurdex is a 700 mcg dexamethasone intravitreal implant, approved for the management of macular edema secondary to retinal vein occlusion, and other related pathoglogiesAnterior chamber dislocation of Ozurdex represents an uncommon complication of the intravitreal injection, which can be managed by repositioning the implant into the vitreous cavity. We describe the case of a successful repositioning of an Ozurdex implant by mobilization and subsequent balanced saline solution injection in the anterior chamber. CASE PRESENTATION An 83-year-old white woman presented to our Emergency Unit complaining of pain and vision loss in herright eye lasting a week. Her anamnesis revealed a history of persistent cystoid macular edema after phacoemulsification with scleral-fixated posterior chamber intraocular lens implantation, recently treated with an intravitreal Ozurdex implant. She also took a long-distance flight 2 days after the injection. An anterior segment examination showed corneal edema and the rod implant adherent to corneal endothelium. To avoid corneal decompensation, we opted for a implant repositioning. Under topical anesthesia, a 30-gauge needle was introduced through a limbar incisionto mobilize the dislocated rod. Balanced saline solution was injected, with a successful repositioning of the implant into the vitreous cavity. Topical 5 % hypertonic saline solution and 0.2 % betamethasone associated with 0.5 % chloramphenicol drops were administered four times a day. To prevent redislocation of the Ozurdex implant, she was instructed to avoid prone position, any kind of physical effort, and not to undertake long-distance flights during the first postoperative week. One week after surgery, an anterior segment examination showed an improvement of corneal edema. Funduscopy showed that the Ozurdex implant was settled into the vitreous cavity. CONCLUSIONS Anterior chamber dislocation of Ozurdex from the vitreous cavity is rare. In our patient, in addition to the posterior capsule tearing, the long-distance flight could have contributed to implant dislocation. Repositioning of the implant is necessary to avoid endothelial decompensation. It can be carried out by using saline balanced solution with the same efficacy as other surgical procedures reported in the literature. A possible disadvantage of this procedure could be implant migration.
منابع مشابه
Corneal graft failure due to migration of Ozurdex™ implant into the anterior chamber
Purpose We report a case of corneal endothelial graft failure secondary to dexamethasone intravitreal implant (Ozurdex™) migration into the anterior chamber (AC). Observations A 53-year-old man with a history of bilateral idiopathic chronic uveitis, had a right anterior vitrectomy and AC intraocular lens (ACIOL) with a peripheral iridotomy. He received an intravitreal Ozurdex™ implant for rig...
متن کاملAcute retinal necrosis following intravitreal dexamethasone (Ozurdex®) implant.
A 52-year-old woman undergoing azathioprine treatment for rheumatoid arthritis developed acute retinal necrosis a month after intravitreal dexamethasone (Ozurdex ®) implantation for posterior uveitis in the left eye. Varicella zoster virus (VZV) DNA was detected in the anterior chamber and vitreous samples on polymerase chain reaction (PCR) analysis. Retinal detachment occurred despite systemic...
متن کاملManagement of a Congenitally Missing Lateral Incisor with Orthodontics, Bone Grafting (a New Method) and Single-Tooth Implant: A Case Report
Careful treatment planning, space management, augmentation of bone and attention to the details of implant surgical and prosthetic techniques are important factors when treating anterior maxilla specially replacement of missing teeth. This case report addresses a chair-side ridge augmentation procedure using autograft bone harvested with trephine drills and placed without using screws and the f...
متن کاملIntralenticular Sustained-Release Dexamethasone Implant: Is It Still Effective on Macular Edema?
PURPOSE To report the therapeutic efficacy of an accidentally injected intralenticular sustained-release dexamethasone implant in a patient with macular edema secondary to branch retinal vein occlusion and shortly discuss the management strategy of this rare complication. METHODS Complete ophthalmological examination and optical coherence tomography imaging were performed at each visit. RES...