Micro-CT vs. Whole Body Multirow Detector CT for Analysing Bone Regeneration in an Animal Model
نویسندگان
چکیده
OBJECTIVES Compared with multirow detector CT (MDCT), specimen (ex vivo) micro-CT (μCT) has a significantly higher (~ 30 x) spatial resolution and is considered the gold standard for assessing bone above the cellular level. However, it is expensive and time-consuming, and when applied in vivo, the radiation dose accumulates considerably. The aim of this study was to examine whether the lower resolution of the widely used MDCT is sufficient to qualitatively and quantitatively evaluate bone regeneration in rats. METHODS Forty critical-size defects (5mm) were placed in the mandibular angle of rats and covered with coated bioactive titanium implants to promote bone healing. Five time points were selected (7, 14, 28, 56 and 112 days). μCT and MDCT were used to evaluate the defect region to determine the bone volume (BV), tissue mineral density (TMD) and bone mineral content (BMC). RESULTS MDCT constantly achieved higher BV values than μCT (10.73±7.84 mm3 vs. 6.62±4.96 mm3, p<0.0001) and consistently lower TMD values (547.68±163.83 mm3 vs. 876.18±121.21 mm3, p<0.0001). No relevant difference was obtained for BMC (6.48±5.71 mm3 vs. 6.15±5.21 mm3, p = 0.40). BV and BMC showed very strong correlations between both methods, whereas TMD was only moderately correlated (r = 0.87, r = 0.90, r = 0.68, p < 0.0001). CONCLUSIONS Due to partial volume effects, MDCT overestimated BV and underestimated TMD but accurately determined BMC, even in small volumes, compared with μCT. Therefore, if bone quantity is a sufficient end point, a considerable number of animals and costs can be saved, and compared with in vivo μCT, the required dose of radiation can be reduced.
منابع مشابه
A Rat Tail Model for Osseointegration Studies and New Bone Formation Follow-up
Animal studies are necessary to precede clinical studies. Recently the rat tail model has been proposed by us as a model for studying bone regeneration with easily surgical approach, effective control of post-operative pain and a decrease of animal number. The present study aimed to widen the rat tail model indication to implant osseointegration. Special titanium implants were inserted through ...
متن کاملEvaluation of Thyroid Hormones, Blood Gases, Body Antioxidant Status, the Activity of Blood Enzymes and Bone Characteristics in Broiler Chickens with Cold Induced Ascites
A total of 150 day old female chickens (Ross 308) were randomly allocated to 2 groups with 5 replicate and 15 chicks in each replicate to determine the effects of cold induced ascites on performance, antioxidant status, blood enzyme activities and bone metabolism. The two experimental treatments were: 1) chicks that reared under normal temperature (NT) and 2) chicks that reared under cold tempe...
متن کاملIncidentally detected inguinal herniation of urinary bladder in whole body skeletal scintigraphy
No abstract
متن کاملQuantitative in vivo micro-computed tomography for assessment of age-dependent changes in murine whole-body composition
Micro-computed tomography (micro-CT) is used routinely to quantify skeletal tissue mass in small animal models. Our goal was to evaluate repeated in vivo micro-CT imaging for monitoring whole-body composition in studies of growth and aging in mice. Male mice from 2 to 52 weeks of age were anesthetized and imaged using an eXplore Locus Ultra and/or eXplore speCZT scanner. Images were reconstruct...
متن کاملCurrent state of bone scintigraphy protocols and practice in Japan
Objective(s): Nuclear medicine technologists in Japan often perform additional single-photon emission computed tomography (SPECT) with or without computed tomography (CT) after whole-body imaging for bone scintigraphy. In this study, we wanted to identify the bone scanning protocols used in Japan, together with the current clinical practices. Methods:...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 11 شماره
صفحات -
تاریخ انتشار 2016