The use of the Geiger - Miiller counter X - ray spectrometer in an X - ray laboratory , with special reference to automatic recording

نویسنده

  • C. WAINWRIGHT
چکیده

The advantages and limitations of Geiger counter techniques in a laboratory applying X-ray methods to a variety of problems are discussed and some simple examples are described. These illustrate the convenience of its use in obtaining semi-quantitative results very rapidly and in following the effects of various treatments. The accuracy of the method is considered in relation to the statistical effects associated with the operation of the Geiger counter and the influence of damping in the recording system. The addition of Geiger-Muller counting devices to X-ray equipment has placed at the disposal of the investigator a means of directly and rapidly estimating X-ray diffraction intensities which he has not possessed since the early ionization chamber technique was generally discarded in favour of the photographic record. Several years' experience with the new technique at the National Physical Laboratory has made it evident that Geiger-Muller counter apparatus has a definite part to play in an X-ray laboratory and that for dealing with certain kinds of problem it has marked advantages over the photographic procedures. The following example is typical of the more straightforward forms of application. A request was received for the examination of six metallic specimens, all somewhat dirty or oxidized, each of which was stated to consist of an iron base with a plated surface layer, probably nickel. The problem was to determine as rapidly as possible whether all the specimens were in fact plated with nickel. One of the specimens was immediately mounted on a Geiger-Muller counter X-ray spectrometer, and on the assumption that nickel diffraction lines would be found, a manual traverse was made over the range 28 = 70"-40" at a rate of approximately 1" in 10 sec, using unfiltered iron radiation. The pen of the automatic recorder was switched on at the same time, but its chart remained stationary, and so long as no diffraction line was encountered, the pen suffered a small deflexion corresponding to background intensity and remained stationary upon the chart except for slight movement due to the natural fluctuations of the counts emerging from the Geiger-Muller counter tube. As soon as a diffraction line was encountered, however, an increasing deflexion was observed, and the effective position and intensity of the line was then determined in a few seconds by successively narrower bracketing traverses across the peak and the angle written down. The chart was then moved forward by hand to a new …

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Local Diagnostic Reference Levels for Common Pediatric X-Ray Examinations in Khorasan Razavi Province, Iran

Introduction Given the fact that children are more sensitive to radiation, compared to adults, special attention needs to be paid to radiation protection in pediatric radiology. Diagnostic reference level (DRL) has been defined to be employed as a practical tool for examining the overall performance of a radiological center in terms of patient dose among a series of similar equipments in an are...

متن کامل

Evaluation of X-Ray Radiation Levels in Radiology Departments of Two Educational Hospitals in Ahvaz, Iran

Introduction: The ionizing radiation is increasingly applied in various fields for industrial and medical purposes due to its benefits. The aim of this study was to measure the radiation levels in six radiology departments of two educational hospitals in Ahvaz, Iran. Materials and Methods: The radiation levels were measured at six locations of six radiology departments, including behind the pat...

متن کامل

Entrance surface dose measurements for routine X-ray examinations in Chaharmahal and Bakhtiari hospitals

Background: There is not any report on the radiation doses received by patients in diagnostic radiology sections in hospitals under control of Chaharmahal and Bakhtiari Medical Sciences University, in the south west of Iran. Objectives: The aim of this study is measurement of entrance surface doses (ESD) for the most routine types of X-ray procedures in radiology centers as part of ongoing d...

متن کامل

Paediatric Dose AssessmentToward Establishment of National Diagnostic Reference Levels for Digital Radiography Examinations in Iran

Introduction: Paediatric patients deserve special attention because of the higher radiation risks compared with adults. The main purpose of this study is to determine patient dose and diagnostic reference level for Paediatric through Entrance Surface Dose (ESD) calculations in common X-ray examination and to establish Paediatric national DRLs in digital radiography in Iran. <...

متن کامل

Evaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013

Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1951