Development of a particle filter framework for respiratory motion correction in nuclear medicine imaging
نویسندگان
چکیده
This research aims to develop a methodological framework based on a data driven approach known as particle filters, often found in computer vision methods, to correct the effect of respiratory motion on Nuclear Medicine imaging data. Particles filters are a popular class of numerical methods for solving optimal estimation problems and we wish to use their flexibility to make an adaptive framework. In this work we use the particle filter for estimating the deformation of the internal organs of the human torso, represented by X, over a discrete time index k. The particle filter approximates the distribution of the deformation of internal organs by generating many propositions, called particles. The posterior estimate is inferred from an observation Zk of the external torso surface. We demonstrate two preliminary approaches in tracking organ deformation. In the first approach, Xk represent a small set of organ surface points. In the second approach, Xk represent a set of affine organ registration parameters to a reference time index r. Both approaches are contrasted to a comparable technique using direct mapping to infer Xk from the observation Zk. Simulations of both approaches using the XCAT phantom suggest that the particle filter-based approaches, on average performs, better.
منابع مشابه
Recursive Bayesian Estimation for Respiratory Motion Correction in Nuclear Medicine
Respiratory motion correction degrades quantitatively and qualitatively Nuclear Medicine images. We propose that adaptive approaches are required to correct for the irregular breathing patterns often encountered in the clinical setting, which can be addressed within a Bayesian tracking formulation. This allows inference of the hidden organ configurations using only knowledge of an external obse...
متن کاملAdvanced Motion Correction Methods in PET
With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of ...
متن کاملAn iterative particle filter approach for respiratory motion estimation in nuclear medicine imaging
The continual improvement in spatial resolution of Nuclear Medicine (NM) scanners has made accurate compensation of patient motion increasingly important. A major source of corrupting motion in NM acquisition is due to respiration. Therefore a particle filter (PF) approach has been proposed as a powerful method for motion correction in NM. The probabilistic view of the system in the PF is seen ...
متن کاملReducing the respiratory motion artifacts in PET cardiology: A simulation study
Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...
متن کاملImpact of PET - CT motion correction in minimising the gross tumour volume in non-small cell lung cancer
AbstractObjective: To investigate the impact of respiratory motion on localization, and quantification lung lesions for the Gross Tumour Volume utilizing an in-house developed Auto3Dreg programme and dynamic NURBS-based cardiac-torso digitised phantom (NCAT). Methods: Respiratory motion may result in more than 30% underestimation of the SUV values of lung, liver and kidney tumour lesions. The m...