Emmetropisation, axial length, and corneal topography in teenagers with Down's syndrome.

نویسندگان

  • S J Doyle
  • J Bullock
  • C Gray
  • A Spencer
  • C Cunningham
چکیده

AIM To study the refractive status and corneal topography in Down's syndrome. METHOD A matched cohort subgroup of 50 individuals with Down's syndrome in the Manchester area aged 15-22 years was studied by refraction, corneal topography, A-scan biometry, slit lamp examination, and orthoptic examination. RESULTS (1) A linear relation was found between axial length and spherical equivalent refraction. There was no statistical relation between keratometry and the axial length. (2) 80% of the group had a hyperopic refraction (mean +2.46 D, range +0.5 to +7.5 D); 18% were myopic (mean -2.75 D, range -0.5 to -8.0 D); and 2% were emmetropic (within plus or minus 0.5 D of zero). The overall mean spherical equivalent refraction was +1.43 (SD 2.86) D. 63% of eyes could see 6/12 or better and 66% of the individuals had a binocular vision of 6/12 or better. (3) Corneal topography was generally of a regular "bow tie" pattern, but there was a high incidence of oblique cylinders. Mean cylinder strength was 1.14 (1.15) D. (4) The prevalence of overt keratoconus was 2%. 6% had corneal topography with inferior steepening which may be a preclinical keratoconic process. CONCLUSIONS In this cohort of late teenagers with Down's syndrome, emmetropisation has failed to occur in most individuals. In a similar aged group of non-disabled individuals one would expect about 83% emmetropic (plus or minus 0.25 D), 13% myopic, and 4% hyperopic. The wide spread of oblique cylinders and the small proportion of with the rule astigmatism is probably related to this failure of emmetropisation. The prevalence of 2% keratoconus in Down's syndrome compares with that found by other authors of between 5.5 and 15%. The 6% with inferior steepening on topography will be followed up over the next few years to see if there is any development of clinical keratoconus. Hence we will see if corneal topography is useful as a screening tool for preclinical keratoconus in this high risk group.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Axial Length in Orthokeratology Patients: Large Case Series

Methods: Patient records were identified from a specialty contact lens practice. Data were obtained from myopic patients who were prescribed Ortho-K wear. Demographic data at baseline included age at commencement of Ortho-K and ethnicity. Clinical data recorded at baseline and at years 1, 2 and 3 included subjective refraction, corneal topography, corneal curvature, axial length, pupil size, an...

متن کامل

Analysis of changes in corneal shape and refraction following scleral buckling surgery.

PURPOSE A prospective study was performed to investigate changes in corneal shape and axial length following scleral buckling surgery. METHODS We investigated the changes in corneal shape, refraction, and axial length following scleral buckling surgery in 24 patients who underwent local buckling and 14 patients who underwent encircling with additional segmental buckling. The corneal shape was...

متن کامل

Myopic versus hyperopic eyes: axial length, corneal shape and optical aberrations.

This study investigated differences in geometrical properties and optical aberrations between a group of hyperopes and myopes (age-matched 30.3+/-5.2 and 30.5+/-3.8 years old, respectively, and with similar absolute refractive error 3.0+/-2.0 and -3.3+/-2.0, respectively). Axial length (AL) was measured by means of optical biometry, and corneal apical radius of curvature (CR) and asphericity (Q...

متن کامل

Corneal topography and myopia. A cross-sectional study.

PURPOSE Central corneal curvature is known to vary with refractive error, but the relation between corneal topography and ametropia is less clear. The current study was conducted to determine whether a relation exists between corneal asphericity and myopia. Associations between corneal asphericity and each of the components of refraction also were examined. METHODS Corneal asphericity and api...

متن کامل

Accuracy of optical biometry combined with Placido disc corneal topography for intraocular lens power calculation

PURPOSE To investigate the accuracy of a new optical biometer for intraocular lens (IOL) power calculation in eyes undergoing cataract surgery. METHODS Consecutive eyes of patients undergoing cataract surgery with the same IOL model were enrolled in a prospective cohort study. Axial length (AL) and corneal power were measured with an optical biometer based on optical low-coherence interferome...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 82 7  شماره 

صفحات  -

تاریخ انتشار 1998