On coronal structures and their variability in active stars: the case of Capella observed with Chandra/LETGS

نویسندگان

  • C. Argiroffi
  • A. Maggio
  • G. Peres
چکیده

In this paper we present a detailed analysis of two X-ray spectra of Capella, taken eleven months apart with the Low Energy Transmission Grating Spectrometer (LETGS) of the Chandra Observatory. We have studied variability of the coronal emission over different time scales, both in the whole X-ray band and in narrow temperature ranges identified by lines. The comparison of the two observations shows that the whole coronal emission of Capella in March 2000 was 3% higher than in February 2001; there also appears to be a tendency, albeit a marginal one, for the hottest lines to show the largest changes between the two observations. A detailed search for short-term variability (on time scales ranging from 10 to 10s) in the emission of individual lines shows that in all cases the emission is compatible with a constant source; the firm upper limits of 5% − 10% to the source variability on short time scales suggests that the intense X-ray emission is due to stable coronal structures and not to flaring activity. We have also determined the coronal thermal structure, as described with the emission measure distribution vs. temperature and with the help of plasma density, derived from the analysis of the O , Ne , Mg  and Si  He-like ion triplets. The emission measure distribution, em(T ), and the element abundances, have been reconstructed with the Markov-Chain Monte Carlo method by Kashyap & Drake; the em(T ) presents a previously known sharp peak around log T = 6.8 − 6.9, but we have also found evidence of a small amount of plasma at T > 107 K. With the help of the em(T ) and the density values we have estimated the pressure and volume of the emitting plasma at different temperatures, and we have derived information about the structure of individual loops and about the population of loops having different maximum temperatures. Our results indicate that loops with higher maximum temperature have higher pressure and smaller volume than lower temperature loops.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling the Ne Ix Triplet Spectral Region of Capella with the Chandra and Xmm-newton Gratings

High resolution X-ray spectroscopy with the diffraction gratings of Chandra and XMM-Newton offers new chances to study a large variety of stellar coronal phenomena. A popular X-ray calibration target is Capella, which has been observed with all gratings with significant exposure times. We gathered together all available data of the HETGS (155 ks), LETGS (219ks), and RGS (53 ks) for comparative ...

متن کامل

Coronal density diagnostics with Si X : CHANDRA / LETGS observations of Procyon , α Cen A & B , Capella and ǫ Eri

Received ; accepted – 2 – ABSTRACT Electron density diagnostics based on a line intensity ratio of Si X are applied to the X-ray spectra of Procyon, α Cen A&B, Capella and ǫ Eri measured with the Low Energy Transmission Grating Spectrometer (LETGS) combined with High-resolution Camera (HRC) on board the Chandra X-ray Observatory. The ratio R 1 of the intensities of the Si X lines at 50.524Å and...

متن کامل

First Light Measurements of Capella with the Low-Energy Transmission Grating Spectrometer aboard the Chandra X-Ray Observatory.

We present the first X-ray spectrum obtained by the Low-Energy Transmission Grating Spectrometer (LETGS) aboard the Chandra X-Ray Observatory. The spectrum is of Capella and covers a wavelength range of 5-175 Å (2.5-0.07 keV). The measured wavelength resolution, which is in good agreement with ground calibration, is Deltalambda approximately 0.06 Å (FWHM). Although in-flight calibration of the ...

متن کامل

High Resolution X-Ray Spectra of Capella: Initial Results from the Chandra High Energy Transmission Grating Spectrometer

High resolution spectra of the active binary Capella (G8 III + G1 III) covering the energy range 0.4-8.0 keV (1.5-30Å) show a large number of emission lines, demonstrating the performance of the HETGS. A preliminary application of plasma diagnostics provides information on coronal temperatures and densities. Lines arising from different elements in a range of ionization states indicate that Cap...

متن کامل

Spectral Indications of Density Variability in the Corona of Ad Leonis

Direct comparison of high-resolution X-ray spectra of the active dMe star AD Leo, observed three times with Chandra, shows variability of key density-sensitive lines, possibly due to flaring activity. In particular, a significant long-duration enhancement of the coronal density is indicated by the Ne IX and Si XIII He-like triplets, and possibly also by density-sensitive Fe XXI line ratios. Sub...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008