Characterization of Solid Renal Masses using 64-Slice Multidetector CT Scanner

نویسندگان

  • Saleh S. El-Esawy
  • Mohamed E. Abou El-Ghar
  • Ghada M. Gaballa
  • Saly A. Zahra
چکیده

The purpose of our study was to assess the role of a 64-slice multidetector CT (MDCT) scanner in the characterization of different solid renal masses, using a simplified approach to correct the postenhancement attenuation values. The study included 96 consecutive adults (58 men, 38 women) with renal masses; 93 with unilateral and three with bilateral masses. All of our patients underwent multiphasic CT study including pre- and postcontrast corticomedullary (CM) and nephrographic phases. We analyzed the images and corrected the postcontrast attenuation values at the CM phase. The postbiopsy or -surgical data were used as reference standard. There were 53 masses at the right kidney, 40 at the left kidney, and three bilateral. The final diagnosis of the 96 solid parenchymal masses were 28 clear-type renal cell carcinoma (RCC), 22 papillary-type RCC, 21 chromophobe-type RCC, six XP 11.2 chromosomal translocation-type RCC, 15 angiomyolipoma (AML), and seven oncocytoma. All the AML had fat, with attenuation values less than -40 HU at the nonenhanced scan. There is no difference in the precontrast attenuation values for the different types other than AML. At the postcontrast CM phase after the correction of the attenuation values, the clear cell type could be separated easily, with attenuation values >20 with specificity, sensitivity, and overall accuracy of 92, 84, and 93%, respectively. The 64-slice MDCT scanner with application of enhancement values correction allows diagnosis of clear cell carcinoma. Also, AML could be identified easily with fat inside at the precontrast scan.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adnexal masses: accuracy of detection and differentiation with multidetector computed tomography.

OBJECTIVE The aim of our study was to evaluate the accuracy of multidetector computed tomography (MDCT) on a 16-row CT scanner in the detection and differentiation of adnexal masses. METHODS We prospectively examined 102 consecutive women with clinically or sonographically detected adnexal masses. Preoperative CT examination was performed, including scanning of the abdomen during the portal p...

متن کامل

Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism

Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...

متن کامل

Adrenal Hemangioma: Findings at Multidetector CT with Short Review of the Literature

We present the computed tomography (CT) imaging findings of a 44-year-old male with incidentally discovered right adrenal hemangioma displaying imaging pattern of nonadenomatous pattern, associated with multiple hepatic hemangiomata using 64-slice multidetector scanner with reviewing published CT imaging findings with short review of the literature.

متن کامل

Evaluation of MRI-based Polymer Gel Dosimetry for Measurement of CT Dose Index (CTDI) on 64 slices CT Scanners

Introduction: Computed tomography (CT) has numerous applications in clinical procedures but its main problem is its high radiation dose to the patients compared to other imaging modalities using x-ray. CT delivers approximately high doses to the nearby tissues due to the scattering effect, fan beam (beam divergence) and limited collimator efficiency. The radiation dose from multi-slice scanners...

متن کامل

Isolated pericardial hydatid cyst: anatomical details on 64 slice multidetector CT scanner.

DESCRIPTION Cardiac involvement is uncommon (0.02–2%) in hydatid disease and the most common location is in the left ventricle, followed by interventricular septum and right ventricle. The clinical presentation of hydatid disease depends on the location of the cysts, and diagnosis is usually made by CT and/or high-resolution MRI. We are presenting an extremely rare manifestation of hydatid dise...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2009