Progressive failure analysis of laminated composite femoral prostheses for total hip arthroplasty.

نویسندگان

  • Chaodi Li
  • Christopher Granger
  • H Del Schutte
  • Sherrill B Biggers
  • John M Kennedy
  • Robert A Latour
چکیده

In this research program, a numerical method was developed to predict the progressive failure of a thick laminated composite femoral component for total hip arthroplasty. A 3-D global/local technique was used to capture the overall structural response of this system while also enabling the 3-D ply level stress state to be determined efficiently and accurately. Different failure criteria and different material degradation models were incorporated as individual subroutines in the numerical method, giving it the flexibility to model a wide range of materials and structures. Numerical modeling was also conducted to design experimental test methods for component fatigue testing that closely simulate in vivo loading conditions. Parametric studies were then conducted with the numerical model of the experimental system and the results were compared to the actual experimentally determined damage behavior of fabricated laminated composite femoral component to assess which parameter set most accurately predicted the actual damage development behavior. The best fitting parameter set was then applied to the failure problem of the composite hip prosthesis implanted in an anatomically modeled femur to predict in vivo performance. This work provides a ply level understanding of the damage behavior of laminated composite femoral components and a numerical tool which can serve as a guide for the design of fatigue resistant implants made from composite material for this and other implant applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Failure analysis of composite femoral components for hip arthroplasty.

In this research, a numerical method was developed for predicting the progressive failure of thick laminated composite femoral components. A three-dimensional (3-D) global/ 3-D local technique was developed to capture the overall structural response of this system, while also enabling the 3-D ply-level stress state to be determined efficiently and accurately. Different failure criteria and mate...

متن کامل

An Affordable Approach for Robust Design of Thick Laminated Composite Structure

A systematic and affordable approach is proposed for the robust design of thick laminated composite structures. Our approach integrates the principles of the Robust Concept Exploration Method (RCEM) for designing complex engineering systems and the hierarchical multi-level optimization procedure for managing the complexity of composite structure optimization. Foundational to the proposed approa...

متن کامل

In-Hospital Outcomes after Hemiarthroplasty versus Total Hip Arthroplasty for Isolated Femoral Neck Fractures

  Background:    Previous studies suggest total hip arthroplasty may have some benefits compared to hemi-arthroplasty for displaced intracapsular femoral neck fractures in patients more than 60 years of age. The primary research question of our study was whether in-hospital adverse events, post-operative length of stay (LOS) and mortality in patients 60 year of age or older differed between tot...

متن کامل

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

Bone density study of the proximal femur after hip arthroplasty with porous-coated implants

Progressive loss of bone mineral density around the femora! component of total hip replacement continues to pose a threat to long term prosthetic survival. A linear study was undertaken to measure bone mineral density on a monthly basis following total hip arthroplasty in 11 male patients. The opposite femur was used as the control measurement. Bone mineral density was unchanged at two mo...

متن کامل