Use of resorbable plates and screws in pediatric facial fractures.

نویسنده

  • Barry L Eppley
چکیده

PURPOSE The use of resorbable plates and screws for fixation of pediatric facial fractures is both well tolerated and effective. It enables realignment and stable positioning of rapidly healing fracture segments while obviating any future issues secondary to long-term metal retention. PATIENTS AND METHODS Forty-four pediatric facial fractures were treated over a 10-year period at our institution using differing techniques of polymeric bone fixation. Twenty-nine mandible fractures in patients under the age of 10 (age range, 6 months to 8 years) were treated. Displaced fractures of the symphysis, parasymphysis, body, and ramus underwent open reduction and either 1.5-mm or 2.0-mm plate and screw fixation in 14 patients. Subcondylar fractures were treated by a short period of maxillomandibular fixation (3 weeks) achieved with suture ligation between resorbable screws placed at the zygoma and symphysis or a circummandibular suture attached to a zygomatic screw. Fifteen patients (age range, 4 to 11 years) with isolated frontal, supraorbital, intraorbital, or orbitozygomatic fractures were treated by open reduction and internal fixation with 1.5-mm resorbable plates, mesh, and screws. RESULTS No long-term implant-related complications were seen in any of the treated patients. CONCLUSIONS Resorbable polylactic and polyglycolic acid plates and screws can be an effective fixation method for facial fractures in children in the primary and secondary dentition periods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تعیین مناسب ترین الگوی توزیع تنش (به روش اجزا محدود) در روش‌های ثابت نمودن با پیچ قابل جذب پس از جراحی ساژیتال دو طرفه راموس

Background and Aim: Due to the complications associated with fixation by Titanium screws and plates in Bilateral Sagittal Split Ramus Osteotomy (BSSRO) surgery, the use of resorbable polymers has been increasingly recommended. Since there are not enough studies on this issue, this study aimed to assess the most appropriate stress distribution in fixation with resorbable screws after BSSRO surge...

متن کامل

Comparison of resorbable plates and titanium plates for fixation stability of combined mandibular symphysis and angle fractures

OBJECTIVES We compared resorbable plates with titanium plates for treatment of combined mandibular angle and symphyseal fractures. MATERIALS AND METHODS Patients with mandibular angle and symphysis fractures were divided into two groups. The control (T) group received titanium plates while the experimental (R) group received resorbable plates. All procedures were carried out under general ane...

متن کامل

The pediatric mandible: II. Management of traumatic injury or fracture.

LEARNING OBJECTIVES After studying this article, the participant should be able to: 1. Describe the changing epidemiology of mandibular fractures in children and adolescents. 2. Discuss the appropriate use of internal fixation in the treatment of pediatric mandibular fractures. 3. Describe the difficulties posed by the deciduous dentition in the use of interdental wiring. 4. Understand reasons ...

متن کامل

Orthodontic and Orthognathic Surgical Treatment of Severe Skeletal Class III with the Use of Resorbable Plates and Screws: A Case Report

This paper presents a case of a female patient with severe skeletal Class III due to pronounced mandibular macrognathia combined with maxillary hypoplasia. The patient was treated with 2-jaw osteotomy in conjunction with preand post-operative orthodontic treatment. Resorbable surgical plates and screws were used for the orthognathic surgery to avoid potential complications from the use of metal...

متن کامل

Use of resorbable implants for mandibular fixation: a systematic review.

Titanium plating is recognized as the criterion standard for the treatment of mandibular fractures and osteotomies. Use of resorbable implants is well documented in the literature for a range of craniofacial fractures. However, no clear review exists of the use of resorbable implants on the mandible. In this systematic review, we searched MEDLINE/PubMed and the Cochrane Database for studies of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons

دوره 63 3  شماره 

صفحات  -

تاریخ انتشار 2005