Uncertainty in liquid chromatographic analysis of pharmaceutical product: influence of various uncertainty sources.

نویسندگان

  • Signe Leito
  • Kadi Mölder
  • Allan Künnapas
  • Koit Herodes
  • Ivo Leito
چکیده

An ISO GUM measurement uncertainty estimation procedure was developed for a liquid-chromatographic drug quality control method-assay of simvastatin in drug formulation. In quantification of uncertainty components several practical approaches for including difficult-to-estimate uncertainty sources (such as uncertainty due to peak integration, uncertainty due to nonlinearity of the calibration curve, etc.) have been presented. Detailed analysis of contributions of the various uncertainty sources was carried out. The results were calculated based on different definitions of the measurand and it was demonstrated that unequivocal definition of the measurand is essential in order to get rigorous uncertainty estimate. Two different calibration methods - single-point (1P) and five-point (5P) - were used and the obtained uncertainties and uncertainty budgets were compared. Results calculated using 1P and 5P calibrations agree very well. The uncertainty estimate for 1P is only slightly larger than with 5P calibration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sources of uncertainty in gas chromatography and high-performance liquid chromatography

Analysts are increasingly being required to evaluate the uncertainty associated with their methods. Indeed, estimating the uncertainty of an analytical result is an essential part of quantitative analysis. The approach of the International Organisation for Standardisation to uncertainty estimation requires the identification of the possible sources of uncertainty for a procedure, followed by th...

متن کامل

A multi-product, multi-period model to select supplier for deteriorating products while considering uncertainty as well as backorder

Determining supplier and optimum order of the quantity is an issue of great importance in logistics management for many companies. In this regard, it is crucial to determine the best decisions for the order quantity as well as the most suitable supplier through considering existing limitations and uncertainties. To optimize a multi-product, multi-period model with select supplier for deteriorat...

متن کامل

Evaluation of Effective Sources in Uncertainty Measurements of Personal Dosimetry by a Harshaw TLD System

Background: The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance.Objective: In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD.Method: T...

متن کامل

Rapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies

A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...

متن کامل

Rapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies

A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1121 1  شماره 

صفحات  -

تاریخ انتشار 2006