Intercomparison of the LBIR Absolute Cryogenic Radiometers to the NIST Optical Power Measurement Standard
نویسندگان
چکیده
The Low Background Infrared calibration (LBIR) facility at the National Institute of Standards and Technology (NIST) presently maintains four absolute cryogenic radiometers (ACRs) which serve as standard reference detectors for infrared calibrations performed by the facility. The primary standard for optical power measurements at NIST-Gaithersburg has been the High Accuracy Cryogenic Radiometer (HACR). Recently, an improved radiometer, the Primary Optical Watt Radiometer (POWR), has replaced the HACR as the primary standard. In this paper, we present the results of comparisons between the radiometric powers measured by the four ACRs presently maintained by the LBIR facility to that measured by the HACR and POWR. This was done by using a Si photodiode light-trapping detector as a secondary transfer standard to compare the primary national standards to the ACRs maintained by the LBIR facility. The technique used to compare an ACR to the trap detector is described in detail. The absolute optical power measurements are found to be within 0.1 % of the primary standard for all the ACRs examined in this study.
منابع مشابه
Low-Background Temperature Calibration of Infrared Blackbodies
The stability of blackbody sources and their ability to be modeled accurately make them well suited for radiometric calibration activity. However, the implementation of the blackbody in industry or the laboratory may, and often does result in blackbody performance that deviates from ideal. The Low Background Infrared (LBIR) facility at the National Institute of Standards and Technology (NIST) w...
متن کاملAn International Comparison of Absolute Radiant Power Measurement Capabilities
We report the results of an intercomparison of monochromatic radiant power measurement capabilities recently completed by 11 national laboratories. The intercomparison radiometers, distributed in pairs, included an amplifier with six decades of precision gain and one of two types of silicon photodiode (pn or np-type construction). Eleven of the laboratories measured the absolute responsivity of...
متن کاملPicoWatt infrared power measurement using an absolute cryogenic radiometer
We report on initial measurements of the low-temperature thermal properties of a device that is similar to the experimental apparatus used for absolute cryogenic radiometry (ACR) within the Low Background InfraRed (LBIR) facility at NIST. The device consists of a receiver cavity mechanically and thermally connected to a temperature-controlled stage through a thin-walled polyimide tube which ser...
متن کاملComparison of Two Cryogenic Radiometers at NIST
Two cryogenic radiometers from NIST, one from the Optical Technology Division and the other from the Optoelectronics Division, were compared at three visible laser wavelengths. For this comparison, each radiometer calibrated two photodiode trap detectors for spectral responsivity. The calibration values for the two trap detectors agreed within the expanded (k = 2) uncertainties. This paper desc...
متن کاملResults of a CIE Detector Response Intercomparison1
A total of fifteen laboratories participated in the CIE detector response in-tercomparison which was designed to assess the level of agreement among participating laboratories in the absolute measurement (with respect to SI) of photodetector response in the visible spectral region. Most participants were either commercial laboratories or university laboratories with the National Institute of St...